FabDigitFabDigit

Nickel Alloy N06060-CD vs N06060-SR

Nickel Alloy · N06060 temper comparison

N06060-CD and N06060-SR are two conditions of the same nickel alloy grade, N06060: CD (cold drawn) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. N06060-CD is the stronger of the two: yield strength 590 MPa (85.6 ksi) against 480 MPa (69.6 ksi) for N06060-SR, about 23% more; tensile strength follows at 800 MPa (116 ksi) vs 720 MPa (104 ksi). In exchange, N06060-SR is the more ductile: elongation 30% versus 25% for N06060-CD, and N06060-CD is harder (220 HB vs 200 HB). N06060-SR runs hotter in service (650°C vs 540°C continuous).

N06060-CDChoose it when strength drives the design.

N06060-SRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

N06060-CD vs N06060-SR: properties

N06060-CDN06060-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

590 MPa85.6 ksi
480 MPa69.6 ksi

Elongation at Break

25%
30%

Reduction in Area

50%
55%

Shear Strength

510 MPa74 ksi
460 MPa66.7 ksi

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

110 J81.1 ft·lbf
145 J107 ft·lbf

Hardness, Brinell

220 HB
200 HB

Hardness, Rockwell B

97 HRB
93 HRB

Hardness, Vickers

232 HV
210 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 76 GPa11 Msi · Bulk Modulus 196 GPa28.4 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.47 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,354°C2,469 °F · Liquidus Temperature 1,413°C2,575 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

540°C1,004 °F
650°C1,202 °F

Same in both: Thermal Conductivity 14.9 W/m·K8.6 BTU/hr·ft·°F · Specific Heat Capacity 444 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.3 µm/m·K7.4 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1.03×10⁻⁶ Ω·m40.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

76 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
22 / 100

Machinability Rating (AISI 1212 = 100 %)

14%
13%

Weldability

75 / 100
78 / 100

Formability (cold)

45 / 100
55 / 100

Same in both: Brazeability / Solderability 70 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 280 L/kg33.6 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleN06060

N06060-CD vs N06060-SR — frequently asked

Is N06060-CD stronger than N06060-SR?

Yes. N06060-CD has a typical yield strength of 590 MPa (85.6 ksi) against 480 MPa (69.6 ksi) for N06060-SR — about 23% more. Tensile strength is 800 MPa (116 ksi) vs 720 MPa (104 ksi).

Which condition does FabDigit quote by default, CD or SR?

ANN is the default N06060 condition in the FabDigit quote flow (neither CD nor SR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose N06060-CD over N06060-SR?

Pick N06060-CD when strength drives the design. Pick N06060-SR when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in N06060-CD and N06060-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.