FabDigitFabDigit

Nickel Alloy N06060-AW vs N06060-CD

Nickel Alloy · N06060 temper comparison

N06060-AW and N06060-CD are two conditions of the same nickel alloy grade, N06060: AW (as-welded deposit) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. N06060-CD is the stronger of the two: yield strength 590 MPa (85.6 ksi) against 320 MPa (46.4 ksi) for N06060-AW, about 84% more; tensile strength follows at 800 MPa (116 ksi) vs 600 MPa (87 ksi). In exchange, N06060-AW is the more ductile: elongation 33% versus 25% for N06060-CD, and N06060-CD is harder (220 HB vs 170 HB). N06060-AW runs hotter in service (980°C vs 540°C continuous).

N06060-AWChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

N06060-CDChoose it when strength drives the design.

N06060-AW vs N06060-CD: properties

N06060-AWN06060-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
800 MPa116 ksi

Yield Strength (0.2% offset)

320 MPa46.4 ksi
590 MPa85.6 ksi

Elongation at Break

33%
25%

Reduction in Area

45%
50%

Shear Strength

400 MPa58 ksi
510 MPa74 ksi

Fatigue Strength (Endurance Limit)

215 MPa31.2 ksi
320 MPa46.4 ksi

Charpy V-Notch Impact (RT)

120 J88.5 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

170 HB
220 HB

Hardness, Rockwell B

86 HRB
97 HRB

Hardness, Vickers

180 HV
232 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 76 GPa11 Msi · Bulk Modulus 196 GPa28.4 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.47 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,354°C2,469 °F · Liquidus Temperature 1,413°C2,575 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

14.5 W/m·K8.4 BTU/hr·ft·°F
14.9 W/m·K8.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

980°C1,796 °F
540°C1,004 °F

Same in both: Specific Heat Capacity 444 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.3 µm/m·K7.4 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

1.6 % IACS
1.7 % IACS

Electrical Resistivity

1.08×10⁻⁶ Ω·m42.5 µΩ·in
1.03×10⁻⁶ Ω·m40.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

18 / 100
24 / 100

Machinability Rating (AISI 1212 = 100 %)

11%
14%

Weldability

80 / 100
75 / 100

Formability (cold)

50 / 100
45 / 100

Same in both: Brazeability / Solderability 70 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 280 L/kg33.6 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleN06060

N06060-AW vs N06060-CD — frequently asked

Is N06060-CD stronger than N06060-AW?

Yes. N06060-CD has a typical yield strength of 590 MPa (85.6 ksi) against 320 MPa (46.4 ksi) for N06060-AW — about 84% more. Tensile strength is 800 MPa (116 ksi) vs 600 MPa (87 ksi).

Which condition does FabDigit quote by default, AW or CD?

ANN is the default N06060 condition in the FabDigit quote flow (neither AW nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, N06060-AW or N06060-CD?

N06060-CD, by a small margin. Both rate poor for machinability — 24/100 against 18/100 for N06060-AW; for welding the order is N06060-AW first (very good, 80/100) then N06060-CD (very good, 75/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in N06060-AW and N06060-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.