FabDigitFabDigit

Nickel Alloy Mu-metal ANN-H2 vs Mu-metal-H02

Nickel Alloy · Mu-metal temper comparison

Mu-metal ANN-H2 and Mu-metal-H02 are two conditions of the same nickel alloy grade, Mu-metal: ANN-H2 (annealed) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. Mu-metal-H02 is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 250 MPa (36.3 ksi) for Mu-metal ANN-H2, about 124% more; tensile strength follows at 750 MPa (109 ksi) vs 550 MPa (79.8 ksi). In exchange, Mu-metal ANN-H2 is the more ductile: elongation 40% versus 10% for Mu-metal-H02, and Mu-metal-H02 is harder (180 HB vs 115 HB). Mu-metal ANN-H2 runs hotter in service (400°C vs 300°C continuous). On the shop floor, Mu-metal-H02 machines more easily (fair vs poor).

Mu-metal ANN-H2Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Mu-metal-H02Choose it when strength drives the design, or when the part is machined in volume.

Mu-metal ANN-H2 vs Mu-metal-H02: properties

Mu-metal ANN-H2Mu-metal-H02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

550 MPa79.8 ksi
750 MPa109 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
560 MPa81.2 ksi

Elongation at Break

40%
10%

Reduction in Area

65%
40%

Shear Strength

360 MPa52.2 ksi
480 MPa69.6 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

150 J111 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

115 HB
180 HB

Hardness, Rockwell B

65 HRB
92 HRB

Hardness, Vickers

120 HV
190 HV

Same in both: Elastic (Young's) Modulus 215 GPa31.2 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 180 GPa26.1 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.74 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Thermal Conductivity 31 W/m·K17.9 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.7 µm/m·K7.1 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

5.7×10⁻⁷ Ω·m22.4 µΩ·in
5.8×10⁻⁷ Ω·m22.8 µΩ·in

Same in both: Electrical Conductivity 3 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
29%

Weldability

55 / 100
50 / 100

Formability (cold)

80 / 100
45 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 140 MJ/kg60,189 BTU/lb · Embodied Carbon (primary production) 10.5 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleMu-metal

Mu-metal ANN-H2 vs Mu-metal-H02 — frequently asked

Is Mu-metal-H02 stronger than Mu-metal ANN-H2?

Yes. Mu-metal-H02 has a typical yield strength of 560 MPa (81.2 ksi) against 250 MPa (36.3 ksi) for Mu-metal ANN-H2 — about 124% more. Tensile strength is 750 MPa (109 ksi) vs 550 MPa (79.8 ksi).

Which condition does FabDigit quote by default, ANN-H2 or H02?

ANN-H2 is the default Mu-metal condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Mu-metal ANN-H2 or Mu-metal-H02?

Mu-metal-H02. Its machinability rates fair (35/100) against poor (25/100) for Mu-metal ANN-H2; for welding the order is Mu-metal ANN-H2 first (good, 55/100) then Mu-metal-H02 (fair, 50/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Mu-metal ANN-H2 and Mu-metal-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.