Nickel Alloy · Monel 400 temper comparison

Monel 400 Cold Drawn and Monel 400-O are two conditions of the same nickel alloy grade, Monel 400: Cold Drawn versus O (annealed). The chemistry is identical, so every difference below comes from the condition. Monel 400 Cold Drawn is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 240 MPa (34.8 ksi) for Monel 400-O, about 100% more; tensile strength follows at 690 MPa (100 ksi) vs 550 MPa (79.8 ksi). In exchange, Monel 400-O is the more ductile: elongation 45% versus 25% for Monel 400 Cold Drawn, and Monel 400 Cold Drawn is harder (200 HB vs 125 HB). On the shop floor, Monel 400-O welds better (82 vs 72 out of 100).

Monel 400 Cold DrawnChoose it when strength drives the design.

Monel 400-OChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

Monel 400 Cold Drawn vs Monel 400-O: properties

Monel 400 Cold DrawnMonel 400-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

690 MPa100 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
240 MPa34.8 ksi

Elongation at Break

25%
45%

Reduction in Area

55%
65%

Shear Strength

450 MPa65.3 ksi
385 MPa55.8 ksi

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
240 MPa34.8 ksi

Charpy V-Notch Impact (RT)

180 J133 ft·lbf
240 J177 ft·lbf

Hardness, Brinell

200 HB
125 HB

Hardness, Rockwell B

92 HRB
70 HRB

Same in both: Elastic (Young's) Modulus 179 GPa26 Msi · Shear Modulus 66 GPa9.6 Msi · Bulk Modulus 152 GPa22 Msi · Poisson's Ratio 0.32 · Hardness, Vickers 130 HV

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,300°C2,372 °F · Liquidus Temperature 1,350°C2,462 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 21.8 W/m·K12.6 BTU/hr·ft·°F · Specific Heat Capacity 427 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.9 µm/m·K7.7 µin/in·°F · Latent Heat of Fusion 297 J/g128 BTU/lb · Max Service Temperature (continuous) 480°C896 °F · Min Service Temperature -260°C-436 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.2 % IACS · Electrical Resistivity 5.47×10⁻⁷ Ω·m21.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
35%

Weldability

72 / 100
82 / 100

Formability (cold)

45 / 100
85 / 100

Same in both: Brazeability / Solderability 65 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 120 MJ/kg51,591 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleMonel 400

Monel 400 Cold Drawn vs Monel 400-O — frequently asked

Is Monel 400 Cold Drawn stronger than Monel 400-O?

Yes. Monel 400 Cold Drawn has a typical yield strength of 480 MPa (69.6 ksi) against 240 MPa (34.8 ksi) for Monel 400-O — about 100% more. Tensile strength is 690 MPa (100 ksi) vs 550 MPa (79.8 ksi).

Which condition does FabDigit quote by default, Cold Drawn or O?

O is the default Monel 400 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Monel 400 Cold Drawn or Monel 400-O?

Monel 400 Cold Drawn. Its machinability rates fair (38/100) against poor (30/100) for Monel 400-O; for welding the order is Monel 400-O first (very good, 82/100) then Monel 400 Cold Drawn (very good, 72/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Monel 400 Cold Drawn and Monel 400-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.