FabDigitFabDigit

Nickel Alloy M30H-F vs M30H-ST

Nickel Alloy · M30H temper comparison

M30H-F and M30H-ST are two conditions of the same nickel alloy grade, M30H: F (as fabricated) versus ST (solution annealed). The chemistry is identical, so every difference below comes from the condition. M30H-F is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 300 MPa (43.5 ksi) for M30H-ST, about 10% more; tensile strength follows at 570 MPa (82.7 ksi) vs 540 MPa (78.3 ksi). In exchange, M30H-ST is the more ductile: elongation 25% versus 20% for M30H-F, and M30H-F is harder (200 HB vs 180 HB).

M30H-FChoose it when strength drives the design.

M30H-STChoose it when the part is bent, formed or impact-loaded.

M30H-F vs M30H-ST: properties

M30H-FM30H-ST

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

570 MPa82.7 ksi
540 MPa78.3 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
300 MPa43.5 ksi

Elongation at Break

20%
25%

Reduction in Area

25%
32%

Shear Strength

360 MPa52.2 ksi
345 MPa50 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
195 MPa28.3 ksi

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

200 HB
180 HB

Hardness, Rockwell C

14 HRC
30 HRC

Same in both: Elastic (Young's) Modulus 172 GPa24.9 Msi · Shear Modulus 66 GPa9.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,180°C2,156 °F · Liquidus Temperature 1,290°C2,354 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

17.5 W/m·K10.1 BTU/hr·ft·°F
18.5 W/m·K10.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 430 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.7 µm/m·K7.6 µin/in·°F · Latent Heat of Fusion 280 J/g120 BTU/lb · Max Service Temperature (continuous) 480°C896 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.7 % IACS
3 % IACS

Electrical Resistivity

6.4×10⁻⁷ Ω·m25.2 µΩ·in
5.8×10⁻⁷ Ω·m22.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
24%

Weldability

28 / 100
30 / 100

Formability (cold)

14 / 100
20 / 100

Same in both: Castability 80 / 100 · Brazeability / Solderability 50 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 130 MJ/kg55,890 BTU/lb · Embodied Carbon (primary production) 11 kg CO₂/kg · Embodied Water 210 L/kg25.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleM30H

M30H-F vs M30H-ST — frequently asked

Is M30H-F stronger than M30H-ST?

Yes. M30H-F has a typical yield strength of 330 MPa (47.9 ksi) against 300 MPa (43.5 ksi) for M30H-ST — about 10% more. Tensile strength is 570 MPa (82.7 ksi) vs 540 MPa (78.3 ksi).

Which condition does FabDigit quote by default, F or ST?

HT is the default M30H condition in the FabDigit quote flow (neither F nor ST). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose M30H-F over M30H-ST?

Pick M30H-F when strength drives the design. Pick M30H-ST when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in M30H-F and M30H-ST side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.