FabDigitFabDigit

Nickel Alloy Inconel X-750-ANN vs Inconel X-750 Spring

Nickel Alloy · Inconel X-750 temper comparison

Inconel X-750-ANN and Inconel X-750 Spring are two conditions of the same nickel alloy grade, Inconel X-750: ANN (annealed) versus Spring (spring hard). The chemistry is identical, so every difference below comes from the condition. Inconel X-750 Spring is the stronger of the two: yield strength 1,170 MPa (170 ksi) against 350 MPa (50.8 ksi) for Inconel X-750-ANN, about 3.3 times as much; tensile strength follows at 1,380 MPa (200 ksi) vs 830 MPa (120 ksi). In exchange, Inconel X-750-ANN is the more ductile: elongation 45% versus 6% for Inconel X-750 Spring, and Inconel X-750 Spring is harder (390 HB vs 180 HB). Inconel X-750-ANN runs hotter in service (870°C vs 540°C continuous). On the shop floor, Inconel X-750-ANN machines more easily (poor vs not recommended) and Inconel X-750-ANN welds better (good vs poor).

Inconel X-750-ANNChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Inconel X-750 SpringChoose it when strength drives the design.

Inconel X-750-ANN vs Inconel X-750 Spring: properties

Inconel X-750-ANNInconel X-750 Spring

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

830 MPa120 ksi
1,380 MPa200 ksi

Yield Strength (0.2% offset)

350 MPa50.8 ksi
1,170 MPa170 ksi

Elongation at Break

45%
6%

Reduction in Area

55%
30%

Compressive Strength

850 MPa123 ksi
1,200 MPa174 ksi

Shear Strength

520 MPa75.4 ksi
830 MPa120 ksi

Fatigue Strength (Endurance Limit)

310 MPa45 ksi
550 MPa79.8 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

110 J81.1 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

180 HB
390 HB

Hardness, Rockwell C

32 HRC
42 HRC

Hardness, Vickers

320 HV
412 HV

Same in both: Elastic (Young's) Modulus 214 GPa31 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 170 GPa24.7 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 8.28 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,393°C2,539 °F · Liquidus Temperature 1,427°C2,601 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

870°C1,598 °F
540°C1,004 °F

Same in both: Thermal Conductivity 12 W/m·K6.9 BTU/hr·ft·°F · Specific Heat Capacity 431 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.6 µm/m·K7 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1.22×10⁻⁶ Ω·m48 µΩ·in
1.23×10⁻⁶ Ω·m48.4 µΩ·in

Same in both: Electrical Conductivity 1.4 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

80 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
10%

Weldability

60 / 100
25 / 100

Formability (cold)

65 / 100
25 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 50 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 190 MJ/kg81,685 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 800 L/kg95.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleInconel X-750

Inconel X-750-ANN vs Inconel X-750 Spring — frequently asked

Is Inconel X-750 Spring stronger than Inconel X-750-ANN?

Yes. Inconel X-750 Spring has a typical yield strength of 1,170 MPa (170 ksi) against 350 MPa (50.8 ksi) for Inconel X-750-ANN — about 3.3 times as much. Tensile strength is 1,380 MPa (200 ksi) vs 830 MPa (120 ksi).

Which condition does FabDigit quote by default, ANN or Spring?

STA is the default Inconel X-750 condition in the FabDigit quote flow (neither ANN nor Spring). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Inconel X-750-ANN or Inconel X-750 Spring?

Inconel X-750-ANN. Its machinability rates poor (22/100) against not recommended (12/100) for Inconel X-750 Spring; for welding the order is Inconel X-750-ANN first (good, 60/100) then Inconel X-750 Spring (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Inconel X-750-ANN and Inconel X-750 Spring side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.