FabDigitFabDigit

Nickel Alloy IN-713C-HIP vs IN-713C-SR

Nickel Alloy · IN-713C temper comparison

IN-713C-HIP and IN-713C-SR are two conditions of the same nickel alloy grade, IN-713C: HIP (hot isostatic pressed) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. IN-713C-HIP is the stronger of the two: tensile strength 910 MPa (132 ksi) against 860 MPa (125 ksi) for IN-713C-SR, about 6% more. IN-713C-HIP is the more ductile: elongation 10% versus 8% for IN-713C-SR, and IN-713C-HIP is harder (35 HRC vs 33 HRC).

IN-713C-HIPChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

IN-713C-HIP vs IN-713C-SR: properties

IN-713C-HIPIN-713C-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

207 GPa30 Msi
205 GPa29.7 Msi

Tensile Strength (Ultimate)

910 MPa132 ksi
860 MPa125 ksi

Yield Strength (0.2% offset)

780 MPa113 ksi
745 MPa108 ksi

Elongation at Break

10%
8%

Reduction in Area

12%
9%

Shear Strength

640 MPa92.8 ksi
600 MPa87 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
310 MPa45 ksi

Fracture Toughness (K_IC)

70 MPa·√m63.7 ksi·√in
60 MPa·√m54.6 ksi·√in

Hardness, Brinell

340 HB
325 HB

Hardness, Rockwell C

35 HRC
33 HRC

Hardness, Vickers

358 HV
345 HV

Same in both: Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 180 GPa26.1 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 7.91 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,260°C2,300 °F · Liquidus Temperature 1,345°C2,453 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

980°C1,796 °F
950°C1,742 °F

Same in both: Thermal Conductivity 10.9 W/m·K6.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.6 µm/m·K5.9 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.3 % IACS · Electrical Resistivity 1.32×10⁻⁶ Ω·m52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

8 / 100
10 / 100

Machinability Rating (AISI 1212 = 100 %)

7%
8%

Weldability

12 / 100
10 / 100

Same in both: Formability (cold) 3 / 100 · Castability 88 / 100 · Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 190 MJ/kg81,685 BTU/lb · Embodied Carbon (primary production) 13.5 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleIN-713C

IN-713C-HIP vs IN-713C-SR — frequently asked

Is IN-713C-HIP stronger than IN-713C-SR?

Yes. IN-713C-HIP has a typical tensile strength of 910 MPa (132 ksi) against 860 MPa (125 ksi) for IN-713C-SR — about 6% more.

Which condition does FabDigit quote by default, HIP or SR?

F is the default IN-713C condition in the FabDigit quote flow (neither HIP nor SR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose IN-713C-HIP over IN-713C-SR?

Pick IN-713C-HIP when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in IN-713C-HIP and IN-713C-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.