FabDigitFabDigit

Magnesium Alloy MB1-H24 vs MB1-O

Magnesium Alloy · MB1 temper comparison

MB1-H24 and MB1-O are two conditions of the same magnesium alloy grade, MB1: H24 (strain hardened and partially annealed, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. MB1-H24 is the stronger of the two: yield strength 180 MPa (26.1 ksi) against 105 MPa (15.2 ksi) for MB1-O, about 71% more; tensile strength follows at 255 MPa (37 ksi) vs 225 MPa (32.6 ksi). In exchange, MB1-O is the more ductile: elongation 12% versus 6% for MB1-H24, and MB1-H24 is harder (48 HB vs 40 HB). MB1-O runs hotter in service (150°C vs 120°C continuous).

MB1-H24Choose it when strength drives the design.

MB1-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

MB1-H24 vs MB1-O: properties

MB1-H24MB1-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

255 MPa37 ksi
225 MPa32.6 ksi

Yield Strength (0.2% offset)

180 MPa26.1 ksi
105 MPa15.2 ksi

Elongation at Break

6%
12%

Compressive Strength

130 MPa18.9 ksi
75 MPa10.9 ksi

Shear Strength

125 MPa18.1 ksi
110 MPa16 ksi

Fatigue Strength (Endurance Limit)

72 MPa10.4 ksi
65 MPa9.4 ksi

Hardness, Brinell

48 HB
40 HB

Same in both: Elastic (Young's) Modulus 45 GPa6.5 Msi · Shear Modulus 17 GPa2.5 Msi · Bulk Modulus 36 GPa5.2 Msi · Poisson's Ratio 0.35 · Fracture Toughness (K_IC) 15 MPa·√m13.7 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 1.76 g/cm³0.06 lb/in³ · Melting Point (Solidus) 648°C1,198 °F · Liquidus Temperature 651°C1,204 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Thermal Conductivity 138 W/m·K79.7 BTU/hr·ft·°F · Specific Heat Capacity 1,000 J/kg·K0.24 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 26 µm/m·K14.4 µin/in·°F · Latent Heat of Fusion 370 J/g159 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 33 % IACS · Electrical Resistivity 5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -1.6 V · Corrosion Resistance 22 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

95 / 100
93 / 100

Weldability

85 / 100
90 / 100

Formability (cold)

20 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 500% · Brazeability / Solderability 25 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 300 MJ/kg128,977 BTU/lb · Embodied Carbon (primary production) 28 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every magnesium alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

701001502001.41.51.61.71.8Density (g/cm³)Yield strength (MPa) — log scaleMB1

MB1-H24 vs MB1-O — frequently asked

Is MB1-H24 stronger than MB1-O?

Yes. MB1-H24 has a typical yield strength of 180 MPa (26.1 ksi) against 105 MPa (15.2 ksi) for MB1-O — about 71% more. Tensile strength is 255 MPa (37 ksi) vs 225 MPa (32.6 ksi).

Which condition does FabDigit quote by default, H24 or O?

O is the default MB1 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, MB1-H24 or MB1-O?

MB1-O. Its weldability rates excellent (90/100) against excellent (85/100) for MB1-H24.

Ready to make it?

Upload a CAD file and FabDigit prices the part in MB1-H24 and MB1-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.