TP1-H01 and TP1-H04 are two conditions of the same copper alloy grade, TP1: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. TP1-H04 is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 175 MPa (25.4 ksi) for TP1-H01, about 71% more; tensile strength follows at 325 MPa (47.1 ksi) vs 250 MPa (36.3 ksi). In exchange, TP1-H01 is the more ductile: elongation 30% versus 6% for TP1-H04, and TP1-H04 is harder (100 HB vs 70 HB). TP1-H01 runs hotter in service (180°C vs 150°C continuous).

TP1-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

TP1-H04Choose it when strength drives the design.

TP1-H01 vs TP1-H04: properties

TP1-H01TP1-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
325 MPa47.1 ksi

Yield Strength (0.2% offset)

175 MPa25.4 ksi
300 MPa43.5 ksi

Elongation at Break

30%
6%

Shear Strength

170 MPa24.7 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
105 MPa15.2 ksi

Hardness, Brinell

70 HB
100 HB

Hardness, Vickers

78 HV
110 HV

Same in both: Elastic (Young's) Modulus 120 GPa17.4 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

350 W/m·K202 BTU/hr·ft·°F
347 W/m·K200 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
150°C302 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

92 % IACS
91 % IACS

Electrical Resistivity

1.87×10⁻⁸ Ω·m0.736 µΩ·in
1.89×10⁻⁸ Ω·m0.744 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
25%

Weldability

95 / 100
90 / 100

Formability (cold)

80 / 100
35 / 100

Same in both: Brazeability / Solderability 98 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.4 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleTP1

TP1-H01 vs TP1-H04 — frequently asked

Is TP1-H04 stronger than TP1-H01?

Yes. TP1-H04 has a typical yield strength of 300 MPa (43.5 ksi) against 175 MPa (25.4 ksi) for TP1-H01 — about 71% more. Tensile strength is 325 MPa (47.1 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, H01 or H04?

H58 is the default TP1 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, TP1-H01 or TP1-H04?

TP1-H04. Its machinability rates fair (40/100) against poor (32/100) for TP1-H01; for welding the order is TP1-H01 first (excellent, 95/100) then TP1-H04 (excellent, 90/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in TP1-H01 and TP1-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.