FabDigitFabDigit

Copper Alloy QBe0.4-TF00 vs QBe0.4-TM08

Copper Alloy · QBe0.4 temper comparison

QBe0.4-TF00 and QBe0.4-TM08 are two conditions of the same copper alloy grade, QBe0.4: TF00 (solution heat treated and precipitation hardened) versus TM08 (mill hardened, spring hard). The chemistry is identical, so every difference below comes from the condition. QBe0.4-TM08 is the stronger of the two: yield strength 760 MPa (110 ksi) against 550 MPa (79.8 ksi) for QBe0.4-TF00, about 38% more; tensile strength follows at 850 MPa (123 ksi) vs 690 MPa (100 ksi). In exchange, QBe0.4-TF00 is the more ductile: elongation 15% versus 8% for QBe0.4-TM08, and QBe0.4-TM08 is harder (240 HB vs 185 HB).

QBe0.4-TF00Choose it when the part is bent, formed or impact-loaded.

QBe0.4-TM08Choose it when strength drives the design.

QBe0.4-TF00 vs QBe0.4-TM08: properties

QBe0.4-TF00QBe0.4-TM08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

690 MPa100 ksi
850 MPa123 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
760 MPa110 ksi

Elongation at Break

15%
8%

Shear Strength

425 MPa61.6 ksi
510 MPa74 ksi

Fatigue Strength (Endurance Limit)

220 MPa31.9 ksi
255 MPa37 ksi

Hardness, Brinell

185 HB
240 HB

Hardness, Rockwell B

92 HRB
100 HRB

Hardness, Vickers

196 HV
262 HV

Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 52 GPa7.5 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,070°C1,958 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

208 W/m·K120 BTU/hr·ft·°F
195 W/m·K113 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.5 µm/m·K9.7 µin/in·°F · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

50 % IACS
46 % IACS

Electrical Resistivity

3.45×10⁻⁸ Ω·m1.36 µΩ·in
3.75×10⁻⁸ Ω·m1.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
35%

Weldability

42 / 100
38 / 100

Formability (cold)

60 / 100
32 / 100

Same in both: Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleQBe0.4

QBe0.4-TF00 vs QBe0.4-TM08 — frequently asked

Is QBe0.4-TM08 stronger than QBe0.4-TF00?

Yes. QBe0.4-TM08 has a typical yield strength of 760 MPa (110 ksi) against 550 MPa (79.8 ksi) for QBe0.4-TF00 — about 38% more. Tensile strength is 850 MPa (123 ksi) vs 690 MPa (100 ksi).

Which condition does FabDigit quote by default, TF00 or TM08?

TM04 is the default QBe0.4 condition in the FabDigit quote flow (neither TF00 nor TM08). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, QBe0.4-TF00 or QBe0.4-TM08?

QBe0.4-TM08, by a small margin. Both rate fair for machinability — 50/100 against 42/100 for QBe0.4-TF00.

Ready to make it?

Upload a CAD file and FabDigit prices the part in QBe0.4-TF00 and QBe0.4-TM08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.