FabDigitFabDigit

Copper Alloy Cu-OF1-H04 vs Cu-OF1-O60

Copper Alloy · Cu-OF1 temper comparison

Cu-OF1-H04 and Cu-OF1-O60 are two conditions of the same copper alloy grade, Cu-OF1: H04 (full hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. Cu-OF1-H04 is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 65 MPa (9.43 ksi) for Cu-OF1-O60, about 4.6 times as much; tensile strength follows at 350 MPa (50.8 ksi) vs 220 MPa (31.9 ksi). In exchange, Cu-OF1-O60 is the more ductile: elongation 50% versus 12% for Cu-OF1-H04, and Cu-OF1-H04 is harder (95 HB vs 42 HB). Cu-OF1-H04 is stiffer (125 GPa vs 117 GPa) and Cu-OF1-O60 runs hotter in service (250°C vs 150°C continuous).

Cu-OF1-H04Choose it when strength drives the design.

Cu-OF1-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Cu-OF1-H04 vs Cu-OF1-O60: properties

Cu-OF1-H04Cu-OF1-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

125 GPa18.1 Msi
117 GPa17 Msi

Tensile Strength (Ultimate)

350 MPa50.8 ksi
220 MPa31.9 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
65 MPa9.4 ksi

Elongation at Break

12%
50%

Reduction in Area

60%
75%

Shear Strength

200 MPa29 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
75 MPa10.9 ksi

Hardness, Brinell

95 HB
42 HB

Hardness, Vickers

105 HV
45 HV

Same in both: Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Hardness, Rockwell B 45 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

388 W/m·K224 BTU/hr·ft·°F
394 W/m·K228 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
250°C482 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

100.2 % IACS
101 % IACS

Electrical Resistivity

1.72×10⁻⁸ Ω·m0.678 µΩ·in
1.71×10⁻⁸ Ω·m0.672 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

27 / 100
18 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
18%

Weldability

68 / 100
72 / 100

Formability (cold)

45 / 100
98 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-OF1

Cu-OF1-H04 vs Cu-OF1-O60 — frequently asked

Is Cu-OF1-H04 stronger than Cu-OF1-O60?

Yes. Cu-OF1-H04 has a typical yield strength of 300 MPa (43.5 ksi) against 65 MPa (9.43 ksi) for Cu-OF1-O60 — about 4.6 times as much. Tensile strength is 350 MPa (50.8 ksi) vs 220 MPa (31.9 ksi).

Which condition does FabDigit quote by default, H04 or O60?

H04 is the default Cu-OF1 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Cu-OF1-H04 or Cu-OF1-O60?

Cu-OF1-H04, by a small margin. Both rate poor for machinability — 27/100 against 18/100 for Cu-OF1-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-OF1-H04 and Cu-OF1-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.