FabDigitFabDigit

Copper Alloy Cu-OF-H02 vs Cu-OF-H10

Copper Alloy · Cu-OF temper comparison

Cu-OF-H02 and Cu-OF-H10 are two conditions of the same copper alloy grade, Cu-OF: H02 (half hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. Cu-OF-H10 is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 250 MPa (36.3 ksi) for Cu-OF-H02, about 48% more; tensile strength follows at 395 MPa (57.3 ksi) vs 285 MPa (41.3 ksi). In exchange, Cu-OF-H02 is the more ductile: elongation 14% versus 3% for Cu-OF-H10, and Cu-OF-H10 is harder (105 HB vs 80 HB). Cu-OF-H10 is stiffer (124 GPa vs 117 GPa) and Cu-OF-H02 runs hotter in service (150°C vs 120°C continuous).

Cu-OF-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Cu-OF-H10Choose it when strength drives the design.

Cu-OF-H02 vs Cu-OF-H10: properties

Cu-OF-H02Cu-OF-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

117 GPa17 Msi
124 GPa18 Msi

Tensile Strength (Ultimate)

285 MPa41.3 ksi
395 MPa57.3 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
370 MPa53.7 ksi

Elongation at Break

14%
3%

Reduction in Area

50%
40%

Shear Strength

180 MPa26.1 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
140 MPa20.3 ksi

Hardness, Brinell

80 HB
105 HB

Hardness, Vickers

85 HV
110 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

385 W/m·K222 BTU/hr·ft·°F
377 W/m·K218 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

100 % IACS
98 % IACS

Electrical Resistivity

1.72×10⁻⁸ Ω·m0.677 µΩ·in
1.76×10⁻⁸ Ω·m0.693 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Weldability

50 / 100
45 / 100

Formability (cold)

60 / 100
20 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-OF

Cu-OF-H02 vs Cu-OF-H10 — frequently asked

Is Cu-OF-H10 stronger than Cu-OF-H02?

Yes. Cu-OF-H10 has a typical yield strength of 370 MPa (53.7 ksi) against 250 MPa (36.3 ksi) for Cu-OF-H02 — about 48% more. Tensile strength is 395 MPa (57.3 ksi) vs 285 MPa (41.3 ksi).

Which condition does FabDigit quote by default, H02 or H10?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, Cu-OF-H02 or Cu-OF-H10?

Cu-OF-H10, by a small margin. Both rate poor for machinability — 30/100 against 25/100 for Cu-OF-H02; for welding the order is Cu-OF-H02 first (fair, 50/100) then Cu-OF-H10 (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-OF-H02 and Cu-OF-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.