FabDigitFabDigit

Copper Alloy Cu-OF-H01 vs Cu-OF-H08

Copper Alloy · Cu-OF temper comparison

Cu-OF-H01 and Cu-OF-H08 are two conditions of the same copper alloy grade, Cu-OF: H01 (quarter hard) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. Cu-OF-H08 is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 195 MPa (28.3 ksi) for Cu-OF-H01, about 74% more; tensile strength follows at 365 MPa (52.9 ksi) vs 260 MPa (37.7 ksi). In exchange, Cu-OF-H01 is the more ductile: elongation 30% versus 4% for Cu-OF-H08, and Cu-OF-H08 is harder (100 HB vs 68 HB). Cu-OF-H01 runs hotter in service (150°C vs 120°C continuous). On the shop floor, Cu-OF-H08 machines more easily (30 vs 20 out of 100).

Cu-OF-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Cu-OF-H08Choose it when strength drives the design, or when the part is machined in volume.

Cu-OF-H01 vs Cu-OF-H08: properties

Cu-OF-H01Cu-OF-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

117 GPa17 Msi
122 GPa17.7 Msi

Tensile Strength (Ultimate)

260 MPa37.7 ksi
365 MPa52.9 ksi

Yield Strength (0.2% offset)

195 MPa28.3 ksi
340 MPa49.3 ksi

Elongation at Break

30%
4%

Reduction in Area

55%
42%

Shear Strength

170 MPa24.7 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
130 MPa18.9 ksi

Hardness, Brinell

68 HB
100 HB

Hardness, Vickers

72 HV
105 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

388 W/m·K224 BTU/hr·ft·°F
380 W/m·K220 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

101 % IACS
99 % IACS

Electrical Resistivity

1.71×10⁻⁸ Ω·m0.673 µΩ·in
1.74×10⁻⁸ Ω·m0.685 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
30%

Weldability

50 / 100
45 / 100

Formability (cold)

80 / 100
25 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-OF

Cu-OF-H01 vs Cu-OF-H08 — frequently asked

Is Cu-OF-H08 stronger than Cu-OF-H01?

Yes. Cu-OF-H08 has a typical yield strength of 340 MPa (49.3 ksi) against 195 MPa (28.3 ksi) for Cu-OF-H01 — about 74% more. Tensile strength is 365 MPa (52.9 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, H01 or H08?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, Cu-OF-H01 or Cu-OF-H08?

Cu-OF-H08, by a small margin. Both rate poor for machinability — 30/100 against 20/100 for Cu-OF-H01; for welding the order is Cu-OF-H01 first (fair, 50/100) then Cu-OF-H08 (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-OF-H01 and Cu-OF-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.