FabDigitFabDigit

Copper Alloy Cu-HCP-H01 vs Cu-HCP-H80

Copper Alloy · Cu-HCP temper comparison

Cu-HCP-H01 and Cu-HCP-H80 are two conditions of the same copper alloy grade, Cu-HCP: H01 (quarter hard) versus H80 (hard drawn). The chemistry is identical, so every difference below comes from the condition. Cu-HCP-H80 is the stronger of the two: yield strength 310 MPa (45 ksi) against 195 MPa (28.3 ksi) for Cu-HCP-H01, about 59% more; tensile strength follows at 345 MPa (50 ksi) vs 260 MPa (37.7 ksi). In exchange, Cu-HCP-H01 is the more ductile: elongation 25% versus 8% for Cu-HCP-H80, and Cu-HCP-H80 is harder (90 HB vs 60 HB).

Cu-HCP-H01Choose it when the part is bent, formed or impact-loaded.

Cu-HCP-H80Choose it when strength drives the design.

Cu-HCP-H01 vs Cu-HCP-H80: properties

Cu-HCP-H01Cu-HCP-H80

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

120 GPa17.4 Msi
125 GPa18.1 Msi

Tensile Strength (Ultimate)

260 MPa37.7 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

195 MPa28.3 ksi
310 MPa45 ksi

Elongation at Break

25%
8%

Shear Strength

170 MPa24.7 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
110 MPa16 ksi

Hardness, Brinell

60 HB
90 HB

Hardness, Vickers

63 HV
95 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

383 W/m·K221 BTU/hr·ft·°F
380 W/m·K220 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 97 % IACS · Electrical Resistivity 1.78×10⁻⁸ Ω·m0.701 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
30 / 100

Weldability

72 / 100
65 / 100

Formability (cold)

72 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Castability 55 / 100 · Brazeability / Solderability 95 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-HCP

Cu-HCP-H01 vs Cu-HCP-H80 — frequently asked

Is Cu-HCP-H80 stronger than Cu-HCP-H01?

Yes. Cu-HCP-H80 has a typical yield strength of 310 MPa (45 ksi) against 195 MPa (28.3 ksi) for Cu-HCP-H01 — about 59% more. Tensile strength is 345 MPa (50 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, H01 or H80?

O60 is the default Cu-HCP condition in the FabDigit quote flow (neither H01 nor H80). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Cu-HCP-H01 or Cu-HCP-H80?

Cu-HCP-H80, by a small margin. Both rate poor for machinability — 30/100 against 25/100 for Cu-HCP-H01; for welding the order is Cu-HCP-H01 first (very good, 72/100) then Cu-HCP-H80 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-HCP-H01 and Cu-HCP-H80 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.