FabDigitFabDigit

Copper Alloy Cu-FRHC-H01 vs Cu-FRHC-H04

Copper Alloy · Cu-FRHC temper comparison

Cu-FRHC-H01 and Cu-FRHC-H04 are two conditions of the same copper alloy grade, Cu-FRHC: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. Cu-FRHC-H04 is the stronger of the two: yield strength 310 MPa (45 ksi) against 210 MPa (30.5 ksi) for Cu-FRHC-H01, about 48% more; tensile strength follows at 345 MPa (50 ksi) vs 265 MPa (38.4 ksi). In exchange, Cu-FRHC-H01 is the more ductile: elongation 25% versus 8% for Cu-FRHC-H04, and Cu-FRHC-H04 is harder (92 HB vs 68 HB). Cu-FRHC-H04 is stiffer (125 GPa vs 117 GPa) and Cu-FRHC-H01 runs hotter in service (200°C vs 150°C continuous).

Cu-FRHC-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Cu-FRHC-H04Choose it when strength drives the design.

Cu-FRHC-H01 vs Cu-FRHC-H04: properties

Cu-FRHC-H01Cu-FRHC-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

117 GPa17 Msi
125 GPa18.1 Msi

Tensile Strength (Ultimate)

265 MPa38.4 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

210 MPa30.5 ksi
310 MPa45 ksi

Elongation at Break

25%
8%

Reduction in Area

55%
75%

Shear Strength

170 MPa24.7 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
110 MPa16 ksi

Hardness, Brinell

68 HB
92 HB

Hardness, Vickers

72 HV
50 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.91 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

388 W/m·K224 BTU/hr·ft·°F
385 W/m·K222 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

100 % IACS
98.5 % IACS

Electrical Resistivity

1.72×10⁻⁸ Ω·m0.679 µΩ·in
1.72×10⁻⁸ Ω·m0.677 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
22 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
25%

Weldability

28 / 100
30 / 100

Formability (cold)

78 / 100
45 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 95 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-FRHC

Cu-FRHC-H01 vs Cu-FRHC-H04 — frequently asked

Is Cu-FRHC-H04 stronger than Cu-FRHC-H01?

Yes. Cu-FRHC-H04 has a typical yield strength of 310 MPa (45 ksi) against 210 MPa (30.5 ksi) for Cu-FRHC-H01 — about 48% more. Tensile strength is 345 MPa (50 ksi) vs 265 MPa (38.4 ksi).

Which condition does FabDigit quote by default, H01 or H04?

O60 is the default Cu-FRHC condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Cu-FRHC-H01 over Cu-FRHC-H04?

Pick Cu-FRHC-H01 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick Cu-FRHC-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-FRHC-H01 and Cu-FRHC-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.