FabDigitFabDigit

Copper Alloy Cu-ETP1 Cast vs Cu-ETP1-M

Copper Alloy · Cu-ETP1 temper comparison

Cu-ETP1 Cast and Cu-ETP1-M are two conditions of the same copper alloy grade, Cu-ETP1: Cast (as cast) versus M (thermomechanically controlled processed). The chemistry is identical, so every difference below comes from the condition. Cu-ETP1-M is the stronger of the two: yield strength 70 MPa (10.2 ksi) against 55 MPa (7.98 ksi) for Cu-ETP1 Cast, about 27% more; tensile strength follows at 220 MPa (31.9 ksi) vs 175 MPa (25.4 ksi). Cu-ETP1-M is the more ductile: elongation 40% versus 30% for Cu-ETP1 Cast, and Cu-ETP1-M is harder (45 HB vs 40 HB). Cu-ETP1-M is stiffer (117 GPa vs 110 GPa).

Cu-ETP1-MChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

Cu-ETP1 Cast vs Cu-ETP1-M: properties

Cu-ETP1 CastCu-ETP1-M

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

110 GPa16 Msi
117 GPa17 Msi

Tensile Strength (Ultimate)

175 MPa25.4 ksi
220 MPa31.9 ksi

Yield Strength (0.2% offset)

55 MPa8 ksi
70 MPa10.2 ksi

Elongation at Break

30%
40%

Reduction in Area

45%
70%

Shear Strength

130 MPa18.9 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
75 MPa10.9 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

40 HB
45 HB

Hardness, Vickers

45 HV
50 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.93 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

391 W/m·K226 BTU/hr·ft·°F
394 W/m·K228 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

101 % IACS
101.5 % IACS

Electrical Resistivity

1.71×10⁻⁸ Ω·m0.672 µΩ·in
1.7×10⁻⁸ Ω·m0.669 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
30 / 100

Weldability

45 / 100
50 / 100

Formability (cold)

55 / 100
95 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Castability 45 / 100 · Brazeability / Solderability 85 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-ETP1

Cu-ETP1 Cast vs Cu-ETP1-M — frequently asked

Is Cu-ETP1-M stronger than Cu-ETP1 Cast?

Yes. Cu-ETP1-M has a typical yield strength of 70 MPa (10.2 ksi) against 55 MPa (7.98 ksi) for Cu-ETP1 Cast — about 27% more. Tensile strength is 220 MPa (31.9 ksi) vs 175 MPa (25.4 ksi).

Which condition does FabDigit quote by default, Cast or M?

M is the default Cu-ETP1 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, Cu-ETP1 Cast or Cu-ETP1-M?

Cu-ETP1-M. Its weldability rates fair (50/100) against fair (45/100) for Cu-ETP1 Cast.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-ETP1 Cast and Cu-ETP1-M side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.