FabDigitFabDigit

Copper Alloy Cu-DXP Cast vs Cu-DXP-M

Copper Alloy · Cu-DXP temper comparison

Cu-DXP Cast and Cu-DXP-M are two conditions of the same copper alloy grade, Cu-DXP: Cast (as cast) versus M (thermomechanically controlled processed). The chemistry is identical, so every difference below comes from the condition. Cu-DXP-M is the stronger of the two: yield strength 80 MPa (11.6 ksi) against 60 MPa (8.7 ksi) for Cu-DXP Cast, about 33% more; tensile strength follows at 210 MPa (30.5 ksi) vs 180 MPa (26.1 ksi). Cu-DXP-M is the more ductile: elongation 40% versus 30% for Cu-DXP Cast, and Cu-DXP-M is harder (48 HB vs 42 HB). Cu-DXP-M is stiffer (117 GPa vs 110 GPa).

Cu-DXP-MChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

Cu-DXP Cast vs Cu-DXP-M: properties

Cu-DXP CastCu-DXP-M

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

110 GPa16 Msi
117 GPa17 Msi

Tensile Strength (Ultimate)

180 MPa26.1 ksi
210 MPa30.5 ksi

Yield Strength (0.2% offset)

60 MPa8.7 ksi
80 MPa11.6 ksi

Elongation at Break

30%
40%

Reduction in Area

40%
70%

Shear Strength

125 MPa18.1 ksi
140 MPa20.3 ksi

Fatigue Strength (Endurance Limit)

58 MPa8.4 ksi
68 MPa9.9 ksi

Hardness, Brinell

42 HB
48 HB

Hardness, Vickers

45 HV
52 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 290 W/m·K168 BTU/hr·ft·°F · Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 70 % IACS · Electrical Resistivity 2.46×10⁻⁸ Ω·m0.969 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
25 / 100

Weldability

82 / 100
88 / 100

Formability (cold)

70 / 100
88 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Castability 70 / 100 · Brazeability / Solderability 95 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-DXP

Cu-DXP Cast vs Cu-DXP-M — frequently asked

Is Cu-DXP-M stronger than Cu-DXP Cast?

Yes. Cu-DXP-M has a typical yield strength of 80 MPa (11.6 ksi) against 60 MPa (8.7 ksi) for Cu-DXP Cast — about 33% more. Tensile strength is 210 MPa (30.5 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, Cast or M?

R220 is the default Cu-DXP condition in the FabDigit quote flow (neither Cast nor M). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, Cu-DXP Cast or Cu-DXP-M?

Cu-DXP-M. Its weldability rates excellent (88/100) against very good (82/100) for Cu-DXP Cast.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-DXP Cast and Cu-DXP-M side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.