FabDigitFabDigit

Copper Alloy Cu-DHP-H02 vs Cu-DHP-H04

Copper Alloy · Cu-DHP temper comparison

Cu-DHP-H02 and Cu-DHP-H04 are two conditions of the same copper alloy grade, Cu-DHP: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. Cu-DHP-H04 is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 250 MPa (36.3 ksi) for Cu-DHP-H02, about 20% more; tensile strength follows at 330 MPa (47.9 ksi) vs 290 MPa (42.1 ksi). In exchange, Cu-DHP-H02 is the more ductile: elongation 14% versus 8% for Cu-DHP-H04, and Cu-DHP-H04 is harder (90 HB vs 80 HB). Cu-DHP-H02 runs hotter in service (140°C vs 120°C continuous).

Cu-DHP-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Cu-DHP-H04Choose it when strength drives the design.

Cu-DHP-H02 vs Cu-DHP-H04: properties

Cu-DHP-H02Cu-DHP-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

290 MPa42.1 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
300 MPa43.5 ksi

Elongation at Break

14%
8%

Shear Strength

185 MPa26.8 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
110 MPa16 ksi

Hardness, Brinell

80 HB
90 HB

Hardness, Vickers

90 HV
100 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

339 W/m·K196 BTU/hr·ft·°F
335 W/m·K194 BTU/hr·ft·°F

Max Service Temperature (continuous)

140°C284 °F
120°C248 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

82 % IACS
81 % IACS

Electrical Resistivity

2.1×10⁻⁸ Ω·m0.827 µΩ·in
2.13×10⁻⁸ Ω·m0.839 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
25%

Weldability

68 / 100
65 / 100

Formability (cold)

75 / 100
60 / 100

Same in both: Brazeability / Solderability 98 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-DHP

Cu-DHP-H02 vs Cu-DHP-H04 — frequently asked

Is Cu-DHP-H04 stronger than Cu-DHP-H02?

Yes. Cu-DHP-H04 has a typical yield strength of 300 MPa (43.5 ksi) against 250 MPa (36.3 ksi) for Cu-DHP-H02 — about 20% more. Tensile strength is 330 MPa (47.9 ksi) vs 290 MPa (42.1 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H58 is the default Cu-DHP condition in the FabDigit quote flow (neither H02 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Cu-DHP-H02 or Cu-DHP-H04?

Cu-DHP-H04. Its machinability rates fair (35/100) against poor (30/100) for Cu-DHP-H02.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-DHP-H02 and Cu-DHP-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.