FabDigitFabDigit

Copper Alloy CC763S-GM vs CC763S-GZ

Copper Alloy · CC763S temper comparison

CC763S-GM and CC763S-GZ are two conditions of the same copper alloy grade, CC763S: GM (gravity die (permanent mould) cast) versus GZ (centrifugally cast). The chemistry is identical, so every difference below comes from the condition. CC763S-GZ is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 330 MPa (47.9 ksi) for CC763S-GM, about 15% more; tensile strength follows at 730 MPa (106 ksi) vs 670 MPa (97.2 ksi). In exchange, CC763S-GM is the more ductile: elongation 14% versus 12% for CC763S-GZ, and CC763S-GZ is harder (170 HB vs 160 HB).

CC763S-GMChoose it when the part is bent, formed or impact-loaded.

CC763S-GZChoose it when strength drives the design.

CC763S-GM vs CC763S-GZ: properties

CC763S-GMCC763S-GZ

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

103 GPa14.9 Msi
105 GPa15.2 Msi

Tensile Strength (Ultimate)

670 MPa97.2 ksi
730 MPa106 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
380 MPa55.1 ksi

Elongation at Break

14%
12%

Reduction in Area

20%
18%

Compressive Strength

420 MPa60.9 ksi
460 MPa66.7 ksi

Shear Strength

440 MPa63.8 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
200 MPa29 ksi

Charpy V-Notch Impact (RT)

22 J16.2 ft·lbf
24 J17.7 ft·lbf

Hardness, Brinell

160 HB
170 HB

Hardness, Rockwell B

83 HRB
87 HRB

Hardness, Vickers

168 HV
178 HV

Same in both: Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 880°C1,616 °F · Liquidus Temperature 910°C1,670 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 60 W/m·K34.7 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 12 % IACS · Electrical Resistivity 1.45×10⁻⁷ Ω·m5.71 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
64 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
28%

Formability (cold)

20 / 100
18 / 100

Same in both: Weldability 30 / 100 · Castability 80 / 100 · Brazeability / Solderability 55 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 48 MJ/kg20,636 BTU/lb · Embodied Carbon (primary production) 3.2 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC763S

CC763S-GM vs CC763S-GZ — frequently asked

Is CC763S-GZ stronger than CC763S-GM?

Yes. CC763S-GZ has a typical yield strength of 380 MPa (55.1 ksi) against 330 MPa (47.9 ksi) for CC763S-GM — about 15% more. Tensile strength is 730 MPa (106 ksi) vs 670 MPa (97.2 ksi).

Which condition does FabDigit quote by default, GM or GZ?

GS is the default CC763S condition in the FabDigit quote flow (neither GM nor GZ). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC763S-GM over CC763S-GZ?

Pick CC763S-GM when the part is bent, formed or impact-loaded. Pick CC763S-GZ when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC763S-GM and CC763S-GZ side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.