FabDigitFabDigit

Copper Alloy CC495K-GS vs CC495K-GZ

Copper Alloy · CC495K temper comparison

CC495K-GS and CC495K-GZ are two conditions of the same copper alloy grade, CC495K: GS (sand cast) versus GZ (centrifugally cast). The chemistry is identical, so every difference below comes from the condition. CC495K-GZ is the stronger of the two: yield strength 130 MPa (18.9 ksi) against 100 MPa (14.5 ksi) for CC495K-GS, about 30% more; tensile strength follows at 260 MPa (37.7 ksi) vs 220 MPa (31.9 ksi). In exchange, CC495K-GS is the more ductile: elongation 12% versus 10% for CC495K-GZ, and CC495K-GZ is harder (72 HB vs 65 HB). CC495K-GZ is stiffer (76 GPa vs 72 GPa).

CC495K-GSChoose it when the part is bent, formed or impact-loaded.

CC495K-GZChoose it when strength drives the design.

CC495K-GS vs CC495K-GZ: properties

CC495K-GSCC495K-GZ

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

72 GPa10.4 Msi
76 GPa11 Msi

Tensile Strength (Ultimate)

220 MPa31.9 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

100 MPa14.5 ksi
130 MPa18.9 ksi

Elongation at Break

12%
10%

Compressive Strength

210 MPa30.5 ksi
245 MPa35.5 ksi

Shear Strength

160 MPa23.2 ksi
185 MPa26.8 ksi

Fatigue Strength (Endurance Limit)

65 MPa9.4 ksi
75 MPa10.9 ksi

Charpy V-Notch Impact (RT)

9 J6.6 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

65 HB
72 HB

Hardness, Rockwell B

22 HRB
29 HRB

Hardness, Vickers

68 HV
77 HV

Same in both: Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 78 GPa11.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.9 g/cm³0.32 lb/in³ · Melting Point (Solidus) 762°C1,404 °F · Liquidus Temperature 930°C1,706 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 47 W/m·K27.2 BTU/hr·ft·°F · Specific Heat Capacity 251 J/kg·K0.06 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.72×10⁻⁷ Ω·m6.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

53 / 100
56 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 85 / 100 · Machinability Rating (AISI 1212 = 100 %) 80% · Weldability 10 / 100 · Formability (cold) 10 / 100 · Castability 88 / 100 · Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC495K

CC495K-GS vs CC495K-GZ — frequently asked

Is CC495K-GZ stronger than CC495K-GS?

Yes. CC495K-GZ has a typical yield strength of 130 MPa (18.9 ksi) against 100 MPa (14.5 ksi) for CC495K-GS — about 30% more. Tensile strength is 260 MPa (37.7 ksi) vs 220 MPa (31.9 ksi).

Which condition does FabDigit quote by default, GS or GZ?

GC is the default CC495K condition in the FabDigit quote flow (neither GS nor GZ). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC495K-GS over CC495K-GZ?

Pick CC495K-GS when the part is bent, formed or impact-loaded. Pick CC495K-GZ when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC495K-GS and CC495K-GZ side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.