FabDigitFabDigit

Copper Alloy CC484K-GM vs CC484K-GZ

Copper Alloy · CC484K temper comparison

CC484K-GM and CC484K-GZ are two conditions of the same copper alloy grade, CC484K: GM (chill / permanent-mould (gravity die) cast) versus GZ (centrifugally cast). The chemistry is identical, so every difference below comes from the condition. Both yield at about 195 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (chill / permanent-mould (gravity die) cast versus centrifugally cast). CC484K-GZ is the more ductile: elongation 10% versus 9% for CC484K-GM, and CC484K-GZ is harder (60 HRB vs 56 HRB).

CC484K-GZChoose it when the part is bent, formed or impact-loaded.

CC484K-GM vs CC484K-GZ: properties

CC484K-GMCC484K-GZ

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

320 MPa46.4 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

195 MPa28.3 ksi
200 MPa29 ksi

Elongation at Break

9%
10%

Reduction in Area

10%
11%

Compressive Strength

480 MPa69.6 ksi
500 MPa72.5 ksi

Shear Strength

235 MPa34.1 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
105 MPa15.2 ksi

Hardness, Brinell

100 HB
105 HB

Hardness, Rockwell B

56 HRB
60 HRB

Hardness, Vickers

105 HV
110 HV

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 40 GPa5.8 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 9 J6.6 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 835°C1,535 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1.72×10⁻⁷ Ω·m6.77 µΩ·in
1.7×10⁻⁷ Ω·m6.69 µΩ·in

Same in both: Electrical Conductivity 10 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

69 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 45 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 20 / 100 · Formability (cold) 5 / 100 · Castability 72 / 100 · Brazeability / Solderability 60 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC484K

CC484K-GM vs CC484K-GZ — frequently asked

What is the difference between CC484K-GM and CC484K-GZ?

CC484K-GM and CC484K-GZ are two conditions of the same copper alloy grade, CC484K: GM (chill / permanent-mould (gravity die) cast) versus GZ (centrifugally cast). The chemistry is identical, so every difference below comes from the condition. Both yield at about 195 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (chill / permanent-mould (gravity die) cast versus centrifugally cast).

Which condition does FabDigit quote by default, GM or GZ?

GZ is the default CC484K condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC484K-GM over CC484K-GZ?

Pick CC484K-GZ when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC484K-GM and CC484K-GZ side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.