FabDigitFabDigit

Copper Alloy CC484K-GM vs CC484K-GS

Copper Alloy · CC484K temper comparison

CC484K-GM and CC484K-GS are two conditions of the same copper alloy grade, CC484K: GM (chill / permanent-mould (gravity die) cast) versus GS (sand cast). The chemistry is identical, so every difference below comes from the condition. CC484K-GM is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 175 MPa (25.4 ksi) for CC484K-GS, about 11% more; tensile strength follows at 320 MPa (46.4 ksi) vs 300 MPa (43.5 ksi). In exchange, CC484K-GS is the more ductile: elongation 10% versus 9% for CC484K-GM, and CC484K-GM is harder (100 HB vs 95 HB).

CC484K-GMChoose it when strength drives the design.

CC484K-GSChoose it when the part is bent, formed or impact-loaded.

CC484K-GM vs CC484K-GS: properties

CC484K-GMCC484K-GS

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

105 GPa15.2 Msi
100 GPa14.5 Msi

Tensile Strength (Ultimate)

320 MPa46.4 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

195 MPa28.3 ksi
175 MPa25.4 ksi

Elongation at Break

9%
10%

Compressive Strength

480 MPa69.6 ksi
450 MPa65.3 ksi

Shear Strength

235 MPa34.1 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
90 MPa13.1 ksi

Charpy V-Notch Impact (RT)

9 J6.6 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

100 HB
95 HB

Hardness, Rockwell B

56 HRB
52 HRB

Hardness, Vickers

105 HV
100 HV

Same in both: Shear Modulus 40 GPa5.8 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34 · Reduction in Area 10%

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 835°C1,535 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 46 W/m·K26.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.72×10⁻⁷ Ω·m6.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

69 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 45 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 20 / 100 · Formability (cold) 5 / 100 · Castability 72 / 100 · Brazeability / Solderability 60 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC484K

CC484K-GM vs CC484K-GS — frequently asked

Is CC484K-GM stronger than CC484K-GS?

Yes. CC484K-GM has a typical yield strength of 195 MPa (28.3 ksi) against 175 MPa (25.4 ksi) for CC484K-GS — about 11% more. Tensile strength is 320 MPa (46.4 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, GM or GS?

GZ is the default CC484K condition in the FabDigit quote flow (neither GM nor GS). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC484K-GM over CC484K-GS?

Pick CC484K-GM when strength drives the design. Pick CC484K-GS when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC484K-GM and CC484K-GS side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.