FabDigitFabDigit

Copper Alloy CC383H-GS vs CC383H-GZ

Copper Alloy · CC383H temper comparison

CC383H-GS and CC383H-GZ are two conditions of the same copper alloy grade, CC383H: GS (sand cast, as-cast) versus GZ (centrifugally cast). The chemistry is identical, so every difference below comes from the condition. CC383H-GZ is the stronger of the two: yield strength 310 MPa (45 ksi) against 290 MPa (42.1 ksi) for CC383H-GS, about 7% more; tensile strength follows at 510 MPa (74 ksi) vs 480 MPa (69.6 ksi). CC383H-GZ is harder — 150 HB against 140 HB for CC383H-GS — which matters for wear surfaces and threads.

CC383H-GZChoose it when strength drives the design, or when surface hardness matters.

CC383H-GS vs CC383H-GZ: properties

CC383H-GSCC383H-GZ

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
510 MPa74 ksi

Yield Strength (0.2% offset)

290 MPa42.1 ksi
310 MPa45 ksi

Elongation at Break

22%
20%

Reduction in Area

25%
22%

Shear Strength

300 MPa43.5 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
160 MPa23.2 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

140 HB
150 HB

Hardness, Rockwell B

77 HRB
81 HRB

Hardness, Vickers

145 HV
156 HV

Same in both: Elastic (Young's) Modulus 150 GPa21.8 Msi · Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 132 GPa19.1 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 8.9 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,170°C2,138 °F · Liquidus Temperature 1,240°C2,264 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.8 µm/m·K8.8 µin/in·°F · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 4.6 % IACS · Electrical Resistivity 3.75×10⁻⁷ Ω·m14.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
79 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
19%

Formability (cold)

25 / 100
22 / 100

Same in both: Weldability 80 / 100 · Castability 62 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 90 MJ/kg38,693 BTU/lb · Embodied Carbon (primary production) 5.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC383H

CC383H-GS vs CC383H-GZ — frequently asked

Is CC383H-GZ stronger than CC383H-GS?

Yes. CC383H-GZ has a typical yield strength of 310 MPa (45 ksi) against 290 MPa (42.1 ksi) for CC383H-GS — about 7% more. Tensile strength is 510 MPa (74 ksi) vs 480 MPa (69.6 ksi).

Which condition does FabDigit quote by default, GS or GZ?

GS is the default CC383H condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC383H-GS over CC383H-GZ?

Pick CC383H-GZ when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC383H-GS and CC383H-GZ side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.