CC382H-GS and CC382H-GZ are two conditions of the same copper alloy grade, CC382H: GS (sand cast, as-cast) versus GZ (centrifugally cast). The chemistry is identical, so every difference below comes from the condition. CC382H-GZ is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 275 MPa (39.9 ksi) for CC382H-GS, about 9% more; tensile strength follows at 500 MPa (72.5 ksi) vs 470 MPa (68.2 ksi). CC382H-GZ is harder — 140 HB against 130 HB for CC382H-GS — which matters for wear surfaces and threads.

CC382H-GZChoose it when strength drives the design, or when surface hardness matters.

CC382H-GS vs CC382H-GZ: properties

CC382H-GSCC382H-GZ

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
500 MPa72.5 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
300 MPa43.5 ksi

Elongation at Break

20%
22%

Reduction in Area

20%
22%

Shear Strength

300 MPa43.5 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

175 MPa25.4 ksi
190 MPa27.6 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

130 HB
140 HB

Hardness, Rockwell B

72 HRB
76 HRB

Hardness, Vickers

137 HV
147 HV

Same in both: Elastic (Young's) Modulus 150 GPa21.8 Msi · Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 132 GPa19.1 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,180°C2,156 °F · Liquidus Temperature 1,240°C2,264 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 26 W/m·K15 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.5 µm/m·K8.6 µin/in·°F · Latent Heat of Fusion 230 J/g98.9 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 4.2 % IACS · Electrical Resistivity 4.1×10⁻⁷ Ω·m16.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

82 / 100
83 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 22 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 65 / 100 · Formability (cold) 10 / 100 · Castability 55 / 100 · Brazeability / Solderability 60 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 85 MJ/kg36,543 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC382H

CC382H-GS vs CC382H-GZ — frequently asked

Is CC382H-GZ stronger than CC382H-GS?

Yes. CC382H-GZ has a typical yield strength of 300 MPa (43.5 ksi) against 275 MPa (39.9 ksi) for CC382H-GS — about 9% more. Tensile strength is 500 MPa (72.5 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, GS or GZ?

GS is the default CC382H condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC382H-GS over CC382H-GZ?

Pick CC382H-GZ when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC382H-GS and CC382H-GZ side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.