FabDigitFabDigit

Copper Alloy C96300-M01 vs C96300-M02

Copper Alloy · C96300 temper comparison

C96300-M01 and C96300-M02 are two conditions of the same copper alloy grade, C96300: M01 (as sand cast) versus M02 (as centrifugally cast). The chemistry is identical, so every difference below comes from the condition. C96300-M02 is the stronger of the two: yield strength 290 MPa (42.1 ksi) against 275 MPa (39.9 ksi) for C96300-M01, about 5% more; tensile strength follows at 500 MPa (72.5 ksi) vs 470 MPa (68.2 ksi). C96300-M02 is the more ductile: elongation 20% versus 18% for C96300-M01, and C96300-M02 is harder (150 HB vs 140 HB).

C96300-M02Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

C96300-M01 vs C96300-M02: properties

C96300-M01C96300-M02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

145 GPa21 Msi
147 GPa21.3 Msi

Tensile Strength (Ultimate)

470 MPa68.2 ksi
500 MPa72.5 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
290 MPa42.1 ksi

Elongation at Break

18%
20%

Reduction in Area

20%
24%

Compressive Strength

285 MPa41.3 ksi
300 MPa43.5 ksi

Shear Strength

300 MPa43.5 ksi
315 MPa45.7 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
165 MPa23.9 ksi

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

140 HB
150 HB

Hardness, Rockwell B

76 HRB
80 HRB

Hardness, Vickers

147 HV
158 HV

Same in both: Shear Modulus 55 GPa8 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.9 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,165°C2,129 °F · Liquidus Temperature 1,205°C2,201 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 33 W/m·K19.1 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.5 µm/m·K8.6 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 6.5 % IACS · Electrical Resistivity 2.65×10⁻⁷ Ω·m10.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
27 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 75 / 100 · Formability (cold) 18 / 100 · Castability 60 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC96300

C96300-M01 vs C96300-M02 — frequently asked

Is C96300-M02 stronger than C96300-M01?

Yes. C96300-M02 has a typical yield strength of 290 MPa (42.1 ksi) against 275 MPa (39.9 ksi) for C96300-M01 — about 5% more. Tensile strength is 500 MPa (72.5 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, M01 or M02?

M01 is the default C96300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C96300-M01 over C96300-M02?

Pick C96300-M02 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C96300-M01 and C96300-M02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.