C96200-M01 and C96200-M07 are two conditions of the same copper alloy grade, C96200: M01 (as sand cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C96200-M07 is the stronger of the two: yield strength 190 MPa (27.6 ksi) against 179 MPa (26 ksi) for C96200-M01, about 6% more; tensile strength follows at 340 MPa (49.3 ksi) vs 317 MPa (46 ksi). C96200-M07 is harder — 85 HB against 80 HB for C96200-M01 — which matters for wear surfaces and threads.

C96200-M07Choose it when strength drives the design, or when surface hardness matters.

C96200-M01 vs C96200-M07: properties

C96200-M01C96200-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

317 MPa46 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

179 MPa26 ksi
190 MPa27.6 ksi

Elongation at Break

25%
27%

Reduction in Area

20%
24%

Shear Strength

230 MPa33.4 ksi
245 MPa35.5 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
118 MPa17.1 ksi

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
75 J55.3 ft·lbf

Hardness, Brinell

80 HB
85 HB

Hardness, Rockwell B

45 HRB
50 HRB

Hardness, Vickers

85 HV
90 HV

Same in both: Elastic (Young's) Modulus 124 GPa18 Msi · Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 120 GPa17.4 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,099°C2,010 °F · Liquidus Temperature 1,149°C2,100 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Max Service Temperature (continuous) 315°C599 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
79 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
22%

Same in both: Weldability 75 / 100 · Castability 60 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC96200

C96200-M01 vs C96200-M07 — frequently asked

Is C96200-M07 stronger than C96200-M01?

Yes. C96200-M07 has a typical yield strength of 190 MPa (27.6 ksi) against 179 MPa (26 ksi) for C96200-M01 — about 6% more. Tensile strength is 340 MPa (49.3 ksi) vs 317 MPa (46 ksi).

Which condition does FabDigit quote by default, M01 or M07?

M01 is the default C96200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C96200-M01 over C96200-M07?

Pick C96200-M07 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C96200-M01 and C96200-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.