FabDigitFabDigit

Copper Alloy C95600-M01 vs C95600-M02

Copper Alloy · C95600 temper comparison

C95600-M01 and C95600-M02 are two conditions of the same copper alloy grade, C95600: M01 (as sand cast) versus M02 (as centrifugally cast). The chemistry is identical, so every difference below comes from the condition. C95600-M02 is the stronger of the two: yield strength 207 MPa (30 ksi) against 193 MPa (28 ksi) for C95600-M01, about 7% more; tensile strength follows at 448 MPa (65 ksi) vs 414 MPa (60 ksi). In exchange, C95600-M01 is the more ductile: elongation 18% versus 16% for C95600-M02.

C95600-M01Choose it when the part is bent, formed or impact-loaded.

C95600-M02Choose it when strength drives the design.

C95600-M01 vs C95600-M02: properties

C95600-M01C95600-M02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

414 MPa60 ksi
448 MPa65 ksi

Yield Strength (0.2% offset)

193 MPa28 ksi
207 MPa30 ksi

Elongation at Break

18%
16%

Shear Strength

290 MPa42.1 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
160 MPa23.2 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

140 HB
145 HB

Hardness, Rockwell B

76 HRB
78 HRB

Hardness, Vickers

146 HV
152 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 7.53 g/cm³0.27 lb/in³ · Melting Point (Solidus) 980°C1,796 °F · Liquidus Temperature 1,010°C1,850 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.5 % IACS · Electrical Resistivity 2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V · Corrosion Resistance 74 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 55 / 100 · Weldability 60 / 100 · Formability (cold) 20 / 100 · Castability 80 / 100 · Brazeability / Solderability 35 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 48 MJ/kg20,636 BTU/lb · Embodied Carbon (primary production) 3.2 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC95600

C95600-M01 vs C95600-M02 — frequently asked

Is C95600-M02 stronger than C95600-M01?

Yes. C95600-M02 has a typical yield strength of 207 MPa (30 ksi) against 193 MPa (28 ksi) for C95600-M01 — about 7% more. Tensile strength is 448 MPa (65 ksi) vs 414 MPa (60 ksi).

Which condition does FabDigit quote by default, M01 or M02?

M01 is the default C95600 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C95600-M01 over C95600-M02?

Pick C95600-M01 when the part is bent, formed or impact-loaded. Pick C95600-M02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C95600-M01 and C95600-M02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.