C94400-M05 and C94400-M07 are two conditions of the same copper alloy grade, C94400: M05 (as plaster cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C94400-M07 is the stronger of the two: yield strength 124 MPa (18 ksi) against 117 MPa (17 ksi) for C94400-M05, about 6% more. In exchange, C94400-M05 is the more ductile: elongation 20% versus 15% for C94400-M07, and C94400-M07 is harder (65 HB vs 60 HB).

C94400-M05Choose it when the part is bent, formed or impact-loaded.

C94400-M07Choose it when strength drives the design.

C94400-M05 vs C94400-M07: properties

C94400-M05C94400-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

234 MPa33.9 ksi
241 MPa35 ksi

Yield Strength (0.2% offset)

117 MPa17 ksi
124 MPa18 ksi

Elongation at Break

20%
15%

Compressive Strength

215 MPa31.2 ksi
228 MPa33.1 ksi

Shear Strength

159 MPa23.1 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

79 MPa11.5 ksi
83 MPa12 ksi

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
9 J6.6 ft·lbf

Hardness, Brinell

60 HB
65 HB

Hardness, Vickers

63 HV
68 HV

Same in both: Elastic (Young's) Modulus 76 GPa11 Msi · Shear Modulus 28 GPa4.1 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.93 g/cm³0.32 lb/in³ · Melting Point (Solidus) 762°C1,404 °F · Liquidus Temperature 954°C1,749 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 47 W/m·K27.2 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Max Service Temperature (continuous) 230°C446 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 12 % IACS · Electrical Resistivity 1.44×10⁻⁷ Ω·m5.67 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 82 / 100 · Machinability Rating (AISI 1212 = 100 %) 80% · Weldability 12 / 100 · Formability (cold) 8 / 100 · Castability 90 / 100 · Brazeability / Solderability 45 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.7 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC94400

C94400-M05 vs C94400-M07 — frequently asked

Is C94400-M07 stronger than C94400-M05?

Yes. C94400-M07 has a typical yield strength of 124 MPa (18 ksi) against 117 MPa (17 ksi) for C94400-M05 — about 6% more. Tensile strength is 241 MPa (35 ksi) vs 234 MPa (33.9 ksi).

Which condition does FabDigit quote by default, M05 or M07?

M01 is the default C94400 condition in the FabDigit quote flow (neither M05 nor M07). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C94400-M05 over C94400-M07?

Pick C94400-M05 when the part is bent, formed or impact-loaded. Pick C94400-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C94400-M05 and C94400-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.