FabDigitFabDigit

Copper Alloy C92600-M01 vs C92600-M07

Copper Alloy · C92600 temper comparison

C92600-M01 and C92600-M07 are two conditions of the same copper alloy grade, C92600: M01 (as sand cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C92600-M07 is the stronger of the two: yield strength 165 MPa (23.9 ksi) against 138 MPa (20 ksi) for C92600-M01, about 20% more. In exchange, C92600-M01 is the more ductile: elongation 30% versus 14% for C92600-M07, and C92600-M07 is harder (80 HB vs 72 HB).

C92600-M01Choose it when the part is bent, formed or impact-loaded.

C92600-M07Choose it when strength drives the design.

C92600-M01 vs C92600-M07: properties

C92600-M01C92600-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

100 GPa14.5 Msi
105 GPa15.2 Msi

Tensile Strength (Ultimate)

303 MPa43.9 ksi
310 MPa45 ksi

Yield Strength (0.2% offset)

138 MPa20 ksi
165 MPa23.9 ksi

Elongation at Break

30%
14%

Compressive Strength

240 MPa34.8 ksi
262 MPa38 ksi

Shear Strength

210 MPa30.5 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
110 MPa16 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

72 HB
80 HB

Hardness, Rockwell B

30 HRB
41 HRB

Hardness, Vickers

76 HV
84 HV

Same in both: Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 854°C1,569 °F · Liquidus Temperature 999°C1,830 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11.5 % IACS
12 % IACS

Electrical Resistivity

1.5×10⁻⁷ Ω·m5.91 µΩ·in
1.44×10⁻⁷ Ω·m5.67 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
72%

Formability (cold)

15 / 100
13 / 100

Same in both: Weldability 30 / 100 · Castability 80 / 100 · Brazeability / Solderability 80 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC92600

C92600-M01 vs C92600-M07 — frequently asked

Is C92600-M07 stronger than C92600-M01?

Yes. C92600-M07 has a typical yield strength of 165 MPa (23.9 ksi) against 138 MPa (20 ksi) for C92600-M01 — about 20% more. Tensile strength is 310 MPa (45 ksi) vs 303 MPa (43.9 ksi).

Which condition does FabDigit quote by default, M01 or M07?

M01 is the default C92600 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C92600-M01 over C92600-M07?

Pick C92600-M01 when the part is bent, formed or impact-loaded. Pick C92600-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C92600-M01 and C92600-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.