FabDigitFabDigit

Copper Alloy C92500-M05 vs C92500-M07

Copper Alloy · C92500 temper comparison

C92500-M05 and C92500-M07 are two conditions of the same copper alloy grade, C92500: M05 (as plaster cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C92500-M07 is the stronger of the two: yield strength 193 MPa (28 ksi) against 165 MPa (23.9 ksi) for C92500-M05, about 17% more; tensile strength follows at 345 MPa (50 ksi) vs 320 MPa (46.4 ksi). In exchange, C92500-M05 is the more ductile: elongation 15% versus 12% for C92500-M07, and C92500-M07 is harder (90 HB vs 85 HB).

C92500-M05Choose it when the part is bent, formed or impact-loaded.

C92500-M07Choose it when strength drives the design.

C92500-M05 vs C92500-M07: properties

C92500-M05C92500-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

320 MPa46.4 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

165 MPa23.9 ksi
193 MPa28 ksi

Elongation at Break

15%
12%

Shear Strength

215 MPa31.2 ksi
230 MPa33.4 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
115 MPa16.7 ksi

Charpy V-Notch Impact (RT)

9 J6.6 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

85 HB
90 HB

Hardness, Rockwell B

45 HRB
50 HRB

Hardness, Vickers

89 HV
95 HV

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 107 GPa15.5 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 831°C1,528 °F · Liquidus Temperature 999°C1,830 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 46.7 W/m·K27 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 11 % IACS · Electrical Resistivity 1.57×10⁻⁷ Ω·m6.18 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

71 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
58%

Same in both: Weldability 25 / 100 · Formability (cold) 5 / 100 · Castability 78 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC92500

C92500-M05 vs C92500-M07 — frequently asked

Is C92500-M07 stronger than C92500-M05?

Yes. C92500-M07 has a typical yield strength of 193 MPa (28 ksi) against 165 MPa (23.9 ksi) for C92500-M05 — about 17% more. Tensile strength is 345 MPa (50 ksi) vs 320 MPa (46.4 ksi).

Which condition does FabDigit quote by default, M05 or M07?

M01 is the default C92500 condition in the FabDigit quote flow (neither M05 nor M07). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C92500-M05 over C92500-M07?

Pick C92500-M05 when the part is bent, formed or impact-loaded. Pick C92500-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C92500-M05 and C92500-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.