C92200-M01 and C92200-M05 are two conditions of the same copper alloy grade, C92200: M01 (as sand cast) versus M05 (as plaster cast). The chemistry is identical, so every difference below comes from the condition. C92200-M05 is the stronger of the two: yield strength 152 MPa (22 ksi) against 138 MPa (20 ksi) for C92200-M01, about 10% more. In exchange, C92200-M01 is the more ductile: elongation 30% versus 24% for C92200-M05, and C92200-M05 is harder (70 HB vs 65 HB).

C92200-M01Choose it when the part is bent, formed or impact-loaded.

C92200-M05Choose it when strength drives the design.

C92200-M01 vs C92200-M05: properties

C92200-M01C92200-M05

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

276 MPa40 ksi
283 MPa41 ksi

Yield Strength (0.2% offset)

138 MPa20 ksi
152 MPa22 ksi

Elongation at Break

30%
24%

Reduction in Area

25%
22%

Compressive Strength

345 MPa50 ksi
360 MPa52.2 ksi

Shear Strength

200 MPa29 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

97 MPa14.1 ksi
100 MPa14.5 ksi

Charpy V-Notch Impact (RT)

16 J11.8 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

65 HB
70 HB

Hardness, Rockwell B

28 HRB
35 HRB

Hardness, Vickers

68 HV
73 HV

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 104 GPa15.1 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.64 g/cm³0.31 lb/in³ · Melting Point (Solidus) 825°C1,517 °F · Liquidus Temperature 990°C1,814 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 41 W/m·K23.7 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 180 J/g77.4 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 14.3 % IACS · Electrical Resistivity 1.21×10⁻⁷ Ω·m4.76 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
69 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 50 / 100 · Machinability Rating (AISI 1212 = 100 %) 42% · Weldability 25 / 100 · Formability (cold) 15 / 100 · Castability 85 / 100 · Brazeability / Solderability 80 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC92200

C92200-M01 vs C92200-M05 — frequently asked

Is C92200-M05 stronger than C92200-M01?

Yes. C92200-M05 has a typical yield strength of 152 MPa (22 ksi) against 138 MPa (20 ksi) for C92200-M01 — about 10% more. Tensile strength is 283 MPa (41 ksi) vs 276 MPa (40 ksi).

Which condition does FabDigit quote by default, M01 or M05?

M01 is the default C92200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C92200-M01 over C92200-M05?

Pick C92200-M01 when the part is bent, formed or impact-loaded. Pick C92200-M05 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C92200-M01 and C92200-M05 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.