C90300-M02 and C90300-M06 are two conditions of the same copper alloy grade, C90300: M02 (as centrifugally cast) versus M06 (as investment cast). The chemistry is identical, so every difference below comes from the condition. C90300-M02 is the stronger of the two: yield strength 155 MPa (22.5 ksi) against 140 MPa (20.3 ksi) for C90300-M06, about 11% more; tensile strength follows at 330 MPa (47.9 ksi) vs 295 MPa (42.8 ksi). C90300-M02 is harder — 75 HB against 70 HB for C90300-M06 — which matters for wear surfaces and threads.

C90300-M02Choose it when strength drives the design, or when surface hardness matters.

C90300-M02 vs C90300-M06: properties

C90300-M02C90300-M06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

105 GPa15.2 Msi
100 GPa14.5 Msi

Tensile Strength (Ultimate)

330 MPa47.9 ksi
295 MPa42.8 ksi

Yield Strength (0.2% offset)

155 MPa22.5 ksi
140 MPa20.3 ksi

Compressive Strength

440 MPa63.8 ksi
400 MPa58 ksi

Shear Strength

230 MPa33.4 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
105 MPa15.2 ksi

Charpy V-Notch Impact (RT)

16 J11.8 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

75 HB
70 HB

Same in both: Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.34 · Elongation at Break 25%

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 854°C1,569 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

75 W/m·K43.3 BTU/hr·ft·°F
74 W/m·K42.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 12 % IACS · Electrical Resistivity 1.44×10⁻⁷ Ω·m5.67 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

12 / 100
15 / 100

Same in both: Machinability 55 / 100 · Weldability 35 / 100 · Castability 85 / 100 · Brazeability / Solderability 82 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC90300

C90300-M02 vs C90300-M06 — frequently asked

Is C90300-M02 stronger than C90300-M06?

Yes. C90300-M02 has a typical yield strength of 155 MPa (22.5 ksi) against 140 MPa (20.3 ksi) for C90300-M06 — about 11% more. Tensile strength is 330 MPa (47.9 ksi) vs 295 MPa (42.8 ksi).

Which condition does FabDigit quote by default, M02 or M06?

M01 is the default C90300 condition in the FabDigit quote flow (neither M02 nor M06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C90300-M02 over C90300-M06?

Pick C90300-M02 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C90300-M02 and C90300-M06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.