FabDigitFabDigit

Copper Alloy C90300-M01 vs C90300-M07

Copper Alloy · C90300 temper comparison

C90300-M01 and C90300-M07 are two conditions of the same copper alloy grade, C90300: M01 (as sand cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C90300-M07 is the stronger of the two: yield strength 172 MPa (24.9 ksi) against 145 MPa (21 ksi) for C90300-M01, about 19% more; tensile strength follows at 330 MPa (47.9 ksi) vs 310 MPa (45 ksi). In exchange, C90300-M01 is the more ductile: elongation 30% versus 16% for C90300-M07, and C90300-M07 is harder (80 HB vs 70 HB).

C90300-M01Choose it when the part is bent, formed or impact-loaded.

C90300-M07Choose it when strength drives the design.

C90300-M01 vs C90300-M07: properties

C90300-M01C90300-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

103 GPa14.9 Msi
105 GPa15.2 Msi

Tensile Strength (Ultimate)

310 MPa45 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

145 MPa21 ksi
172 MPa24.9 ksi

Elongation at Break

30%
16%

Compressive Strength

415 MPa60.2 ksi
455 MPa66 ksi

Shear Strength

220 MPa31.9 ksi
235 MPa34.1 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
120 MPa17.4 ksi

Charpy V-Notch Impact (RT)

15 J11.1 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

70 HB
80 HB

Same in both: Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 854°C1,569 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 75 W/m·K43.3 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 12 % IACS · Electrical Resistivity 1.44×10⁻⁷ Ω·m5.67 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
58 / 100

Formability (cold)

15 / 100
10 / 100

Same in both: Weldability 35 / 100 · Castability 85 / 100 · Brazeability / Solderability 82 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC90300

C90300-M01 vs C90300-M07 — frequently asked

Is C90300-M07 stronger than C90300-M01?

Yes. C90300-M07 has a typical yield strength of 172 MPa (24.9 ksi) against 145 MPa (21 ksi) for C90300-M01 — about 19% more. Tensile strength is 330 MPa (47.9 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, M01 or M07?

M01 is the default C90300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C90300-M01 over C90300-M07?

Pick C90300-M01 when the part is bent, formed or impact-loaded. Pick C90300-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C90300-M01 and C90300-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.