FabDigitFabDigit

Copper Alloy C86800-M01 vs C86800-M07

Copper Alloy · C86800 temper comparison

C86800-M01 and C86800-M07 are two conditions of the same copper alloy grade, C86800: M01 (as sand cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C86800-M07 is the stronger of the two: yield strength 315 MPa (45.7 ksi) against 290 MPa (42.1 ksi) for C86800-M01, about 9% more; tensile strength follows at 600 MPa (87 ksi) vs 565 MPa (81.9 ksi). In exchange, C86800-M01 is the more ductile: elongation 20% versus 18% for C86800-M07, and C86800-M07 is harder (160 HB vs 150 HB).

C86800-M01Choose it when the part is bent, formed or impact-loaded.

C86800-M07Choose it when strength drives the design.

C86800-M01 vs C86800-M07: properties

C86800-M01C86800-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

565 MPa81.9 ksi
600 MPa87 ksi

Yield Strength (0.2% offset)

290 MPa42.1 ksi
315 MPa45.7 ksi

Elongation at Break

20%
18%

Reduction in Area

20%
18%

Compressive Strength

600 MPa87 ksi
635 MPa92.1 ksi

Shear Strength

380 MPa55.1 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
185 MPa26.8 ksi

Charpy V-Notch Impact (RT)

24 J17.7 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

150 HB
160 HB

Hardness, Rockwell B

80 HRB
84 HRB

Hardness, Vickers

158 HV
168 HV

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 875°C1,607 °F · Liquidus Temperature 925°C1,697 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 36 W/m·K20.8 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.5 % IACS · Electrical Resistivity 2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
63 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
38%

Same in both: Weldability 30 / 100 · Castability 75 / 100 · Brazeability / Solderability 50 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC86800

C86800-M01 vs C86800-M07 — frequently asked

Is C86800-M07 stronger than C86800-M01?

Yes. C86800-M07 has a typical yield strength of 315 MPa (45.7 ksi) against 290 MPa (42.1 ksi) for C86800-M01 — about 9% more. Tensile strength is 600 MPa (87 ksi) vs 565 MPa (81.9 ksi).

Which condition does FabDigit quote by default, M01 or M07?

M01 is the default C86800 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C86800-M01 over C86800-M07?

Pick C86800-M01 when the part is bent, formed or impact-loaded. Pick C86800-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C86800-M01 and C86800-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.