FabDigitFabDigit

Copper Alloy C85400-M05 vs C85400-M07

Copper Alloy · C85400 temper comparison

C85400-M05 and C85400-M07 are two conditions of the same copper alloy grade, C85400: M05 (as plaster cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C85400-M07 is the stronger of the two: yield strength 105 MPa (15.2 ksi) against 95 MPa (13.8 ksi) for C85400-M05, about 11% more. In exchange, C85400-M05 is the more ductile: elongation 30% versus 25% for C85400-M07, and C85400-M07 is harder (60 HB vs 55 HB).

C85400-M05Choose it when the part is bent, formed or impact-loaded.

C85400-M07Choose it when strength drives the design.

C85400-M05 vs C85400-M07: properties

C85400-M05C85400-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

95 MPa13.8 ksi
105 MPa15.2 ksi

Elongation at Break

30%
25%

Reduction in Area

26%
22%

Compressive Strength

222 MPa32.2 ksi
235 MPa34.1 ksi

Shear Strength

195 MPa28.3 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

75 MPa10.9 ksi
80 MPa11.6 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

55 HB
60 HB

Hardness, Rockwell B

20 HRB
25 HRB

Hardness, Vickers

58 HV
63 HV

Same in both: Elastic (Young's) Modulus 97 GPa14.1 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.47 g/cm³0.31 lb/in³ · Melting Point (Solidus) 855°C1,571 °F · Liquidus Temperature 940°C1,724 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 87 W/m·K50.3 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.7 µm/m·K11.5 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 21.5 % IACS · Electrical Resistivity 8×10⁻⁸ Ω·m3.15 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

85 / 100
88 / 100

Machinability Rating (AISI 1212 = 100 %)

80%
85%

Same in both: Weldability 20 / 100 · Formability (cold) 15 / 100 · Castability 85 / 100 · Brazeability / Solderability 85 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.2 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 90%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC85400

C85400-M05 vs C85400-M07 — frequently asked

Is C85400-M07 stronger than C85400-M05?

Yes. C85400-M07 has a typical yield strength of 105 MPa (15.2 ksi) against 95 MPa (13.8 ksi) for C85400-M05 — about 11% more. Tensile strength is 260 MPa (37.7 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, M05 or M07?

M01 is the default C85400 condition in the FabDigit quote flow (neither M05 nor M07). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C85400-M05 over C85400-M07?

Pick C85400-M05 when the part is bent, formed or impact-loaded. Pick C85400-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C85400-M05 and C85400-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.