Copper Alloy C85400-M01 vs C85400-M05

Copper Alloy · C85400 temper comparison

C85400-M01 and C85400-M05 are two conditions of the same copper alloy grade, C85400: M01 (as sand cast) versus M05 (as plaster cast). The chemistry is identical, so every difference below comes from the condition. C85400-M05 is the stronger of the two: yield strength 95 MPa (13.8 ksi) against 83 MPa (12 ksi) for C85400-M01, about 14% more; tensile strength follows at 250 MPa (36.3 ksi) vs 234 MPa (33.9 ksi). In exchange, C85400-M01 is the more ductile: elongation 35% versus 30% for C85400-M05, and C85400-M05 is harder (55 HB vs 50 HB).

C85400-M01Choose it when the part is bent, formed or impact-loaded.

C85400-M05Choose it when strength drives the design.

C85400-M01 vs C85400-M05: properties

C85400-M01C85400-M05

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

234 MPa33.9 ksi
250 MPa36.3 ksi

Yield Strength (0.2% offset)

83 MPa12 ksi
95 MPa13.8 ksi

Elongation at Break

35%
30%

Reduction in Area

28%
26%

Compressive Strength

210 MPa30.5 ksi
222 MPa32.2 ksi

Shear Strength

186 MPa27 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
75 MPa10.9 ksi

Hardness, Brinell

50 HB
55 HB

Hardness, Rockwell B

15 HRB
20 HRB

Hardness, Vickers

53 HV
58 HV

Same in both: Elastic (Young's) Modulus 97 GPa14.1 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 30 J22.1 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.47 g/cm³0.31 lb/in³ · Melting Point (Solidus) 855°C1,571 °F · Liquidus Temperature 940°C1,724 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 87 W/m·K50.3 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.7 µm/m·K11.5 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 21.5 % IACS · Electrical Resistivity 8×10⁻⁸ Ω·m3.15 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 85 / 100 · Machinability Rating (AISI 1212 = 100 %) 80% · Weldability 20 / 100 · Formability (cold) 15 / 100 · Castability 85 / 100 · Brazeability / Solderability 85 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.2 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 90%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC85400

C85400-M01 vs C85400-M05 — frequently asked

Is C85400-M05 stronger than C85400-M01?

Yes. C85400-M05 has a typical yield strength of 95 MPa (13.8 ksi) against 83 MPa (12 ksi) for C85400-M01 — about 14% more. Tensile strength is 250 MPa (36.3 ksi) vs 234 MPa (33.9 ksi).

Which condition does FabDigit quote by default, M01 or M05?

M01 is the default C85400 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C85400-M01 over C85400-M05?

Pick C85400-M01 when the part is bent, formed or impact-loaded. Pick C85400-M05 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C85400-M01 and C85400-M05 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.