FabDigitFabDigit

Copper Alloy C84100-M01 vs C84100-M07

Copper Alloy · C84100 temper comparison

C84100-M01 and C84100-M07 are two conditions of the same copper alloy grade, C84100: M01 (as sand cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C84100-M07 is the stronger of the two: yield strength 110 MPa (16 ksi) against 90 MPa (13.1 ksi) for C84100-M01, about 22% more; tensile strength follows at 234 MPa (33.9 ksi) vs 207 MPa (30 ksi). C84100-M07 is harder — 58 HB against 52 HB for C84100-M01 — which matters for wear surfaces and threads.

C84100-M07Choose it when strength drives the design, or when surface hardness matters.

C84100-M01 vs C84100-M07: properties

C84100-M01C84100-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

207 MPa30 ksi
234 MPa33.9 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
110 MPa16 ksi

Elongation at Break

26%
25%

Shear Strength

155 MPa22.5 ksi
170 MPa24.7 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
78 MPa11.3 ksi

Hardness, Brinell

52 HB
58 HB

Hardness, Vickers

55 HV
61 HV

Same in both: Elastic (Young's) Modulus 90 GPa13.1 Msi · Shear Modulus 34 GPa4.9 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 20 J14.8 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.6 g/cm³0.31 lb/in³ · Melting Point (Solidus) 855°C1,571 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 72 W/m·K41.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.7 µm/m·K11.5 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 16.5 % IACS · Electrical Resistivity 1.05×10⁻⁷ Ω·m4.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

57 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

80 / 100
85 / 100

Machinability Rating (AISI 1212 = 100 %)

80%
85%

Same in both: Weldability 25 / 100 · Formability (cold) 15 / 100 · Castability 85 / 100 · Brazeability / Solderability 80 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC84100

C84100-M01 vs C84100-M07 — frequently asked

Is C84100-M07 stronger than C84100-M01?

Yes. C84100-M07 has a typical yield strength of 110 MPa (16 ksi) against 90 MPa (13.1 ksi) for C84100-M01 — about 22% more. Tensile strength is 234 MPa (33.9 ksi) vs 207 MPa (30 ksi).

Which condition does FabDigit quote by default, M01 or M07?

M01 is the default C84100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C84100-M01 or C84100-M07?

C84100-M07. Its machinability rates excellent (85/100) against very good (80/100) for C84100-M01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C84100-M01 and C84100-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.