FabDigitFabDigit

Copper Alloy C83800-M05 vs C83800-M06

Copper Alloy · C83800 temper comparison

C83800-M05 and C83800-M06 are two conditions of the same copper alloy grade, C83800: M05 (as plaster cast) versus M06 (as investment cast). The chemistry is identical, so every difference below comes from the condition. C83800-M05 is the stronger of the two: yield strength 124 MPa (18 ksi) against 110 MPa (16 ksi) for C83800-M06, about 13% more; tensile strength follows at 262 MPa (38 ksi) vs 241 MPa (35 ksi). In exchange, C83800-M06 is the more ductile: elongation 22% versus 18% for C83800-M05, and C83800-M05 is harder (62 HB vs 55 HB).

C83800-M05Choose it when strength drives the design.

C83800-M06Choose it when the part is bent, formed or impact-loaded.

C83800-M05 vs C83800-M06: properties

C83800-M05C83800-M06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

262 MPa38 ksi
241 MPa35 ksi

Yield Strength (0.2% offset)

124 MPa18 ksi
110 MPa16 ksi

Elongation at Break

18%
22%

Compressive Strength

250 MPa36.3 ksi
230 MPa33.4 ksi

Shear Strength

207 MPa30 ksi
193 MPa28 ksi

Fatigue Strength (Endurance Limit)

83 MPa12 ksi
76 MPa11 ksi

Hardness, Brinell

62 HB
55 HB

Same in both: Elastic (Young's) Modulus 90 GPa13.1 Msi · Shear Modulus 34 GPa4.9 Msi · Bulk Modulus 95 GPa13.8 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.6 g/cm³0.31 lb/in³ · Melting Point (Solidus) 843°C1,549 °F · Liquidus Temperature 1,004°C1,839 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 72 W/m·K41.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 15 % IACS · Electrical Resistivity 1.15×10⁻⁷ Ω·m4.53 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

59 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 88 / 100 · Machinability Rating (AISI 1212 = 100 %) 90% · Weldability 20 / 100 · Castability 88 / 100 · Brazeability / Solderability 80 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC83800

C83800-M05 vs C83800-M06 — frequently asked

Is C83800-M05 stronger than C83800-M06?

Yes. C83800-M05 has a typical yield strength of 124 MPa (18 ksi) against 110 MPa (16 ksi) for C83800-M06 — about 13% more. Tensile strength is 262 MPa (38 ksi) vs 241 MPa (35 ksi).

Which condition does FabDigit quote by default, M05 or M06?

M01 is the default C83800 condition in the FabDigit quote flow (neither M05 nor M06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C83800-M05 over C83800-M06?

Pick C83800-M05 when strength drives the design. Pick C83800-M06 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C83800-M05 and C83800-M06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.