C82100-TB00 and C82100-TF00 are two conditions of the same copper alloy grade, C82100: TB00 (solution heat treated) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C82100-TF00 is the stronger of the two: yield strength 515 MPa (74.7 ksi) against 140 MPa (20.3 ksi) for C82100-TB00, about 3.7 times as much; tensile strength follows at 655 MPa (95 ksi) vs 310 MPa (45 ksi). In exchange, C82100-TB00 is the more ductile: elongation 25% versus 6% for C82100-TF00, and C82100-TF00 is harder (200 HB vs 80 HB). C82100-TF00 runs hotter in service (200°C vs 150°C continuous) and C82100-TF00 conducts heat better (208 W/m·K vs 90 W/m·K).

C82100-TB00Choose it when the part is bent, formed or impact-loaded.

C82100-TF00Choose it when strength drives the design, or when the part sees heat.

C82100-TB00 vs C82100-TF00: properties

C82100-TB00C82100-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
655 MPa95 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
515 MPa74.7 ksi

Elongation at Break

25%
6%

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
190 MPa27.6 ksi

Hardness, Brinell

80 HB
200 HB

Hardness, Rockwell B

45 HRB
96 HRB

Same in both: Elastic (Young's) Modulus 131 GPa19 Msi · Shear Modulus 50 GPa7.3 Msi · Bulk Modulus 125 GPa18.1 Msi · Poisson's Ratio 0.3 · Shear Strength 415 MPa60.2 ksi · Charpy V-Notch Impact (RT) 8 J5.9 ft·lbf · Hardness, Rockwell C 20 HRC · Hardness, Vickers 210 HV

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,090°C1,994 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

90 W/m·K52 BTU/hr·ft·°F
208 W/m·K120 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 419 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.8 µm/m·K9.9 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

19 % IACS
45 % IACS

Electrical Resistivity

9.07×10⁻⁸ Ω·m3.57 µΩ·in
3.83×10⁻⁸ Ω·m1.51 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

30%
20%

Formability (cold)

40 / 100
15 / 100

Same in both: Machinability 35 / 100 · Weldability 45 / 100 · Castability 80 / 100 · Brazeability / Solderability 55 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC82100

C82100-TB00 vs C82100-TF00 — frequently asked

Is C82100-TF00 stronger than C82100-TB00?

Yes. C82100-TF00 has a typical yield strength of 515 MPa (74.7 ksi) against 140 MPa (20.3 ksi) for C82100-TB00 — about 3.7 times as much. Tensile strength is 655 MPa (95 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, TB00 or TF00?

TF00 is the default C82100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C82100-TB00 over C82100-TF00?

Pick C82100-TB00 when the part is bent, formed or impact-loaded. Pick C82100-TF00 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C82100-TB00 and C82100-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.