FabDigitFabDigit

Copper Alloy C80500-M02 vs C80500-M03

Copper Alloy · C80500 temper comparison

C80500-M02 and C80500-M03 are two conditions of the same copper alloy grade, C80500: M02 (as centrifugally cast) versus M03 (as chill cast). The chemistry is identical, so every difference below comes from the condition. C80500-M02 is the stronger of the two: yield strength 70 MPa (10.2 ksi) against 60 MPa (8.7 ksi) for C80500-M03, about 17% more; tensile strength follows at 195 MPa (28.3 ksi) vs 175 MPa (25.4 ksi). C80500-M02 is harder — 48 HB against 43 HB for C80500-M03 — which matters for wear surfaces and threads.

C80500-M02Choose it when strength drives the design, or when surface hardness matters.

C80500-M02 vs C80500-M03: properties

C80500-M02C80500-M03

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

117 GPa17 Msi
115 GPa16.7 Msi

Tensile Strength (Ultimate)

195 MPa28.3 ksi
175 MPa25.4 ksi

Yield Strength (0.2% offset)

70 MPa10.2 ksi
60 MPa8.7 ksi

Reduction in Area

48%
45%

Shear Strength

135 MPa19.6 ksi
120 MPa17.4 ksi

Fatigue Strength (Endurance Limit)

68 MPa9.9 ksi
60 MPa8.7 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
43 J31.7 ft·lbf

Hardness, Brinell

48 HB
43 HB

Hardness, Vickers

50 HV
45 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Elongation at Break 40%

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 355 W/m·K205 BTU/hr·ft·°F · Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 92 % IACS · Electrical Resistivity 1.87×10⁻⁸ Ω·m0.736 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 25 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 60 / 100 · Formability (cold) 40 / 100 · Castability 50 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC80500

C80500-M02 vs C80500-M03 — frequently asked

Is C80500-M02 stronger than C80500-M03?

Yes. C80500-M02 has a typical yield strength of 70 MPa (10.2 ksi) against 60 MPa (8.7 ksi) for C80500-M03 — about 17% more. Tensile strength is 195 MPa (28.3 ksi) vs 175 MPa (25.4 ksi).

Which condition does FabDigit quote by default, M02 or M03?

M01 is the default C80500 condition in the FabDigit quote flow (neither M02 nor M03). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C80500-M02 over C80500-M03?

Pick C80500-M02 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C80500-M02 and C80500-M03 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.