C80500-M01 and C80500-M02 are two conditions of the same copper alloy grade, C80500: M01 (as sand cast) versus M02 (as centrifugally cast). The chemistry is identical, so every difference below comes from the condition. C80500-M02 is the stronger of the two: yield strength 70 MPa (10.2 ksi) against 62 MPa (8.99 ksi) for C80500-M01, about 13% more; tensile strength follows at 195 MPa (28.3 ksi) vs 180 MPa (26.1 ksi). C80500-M02 is harder — 48 HB against 44 HB for C80500-M01 — which matters for wear surfaces and threads.

C80500-M02Choose it when strength drives the design, or when surface hardness matters.

C80500-M01 vs C80500-M02: properties

C80500-M01C80500-M02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

180 MPa26.1 ksi
195 MPa28.3 ksi

Yield Strength (0.2% offset)

62 MPa9 ksi
70 MPa10.2 ksi

Reduction in Area

45%
48%

Shear Strength

125 MPa18.1 ksi
135 MPa19.6 ksi

Fatigue Strength (Endurance Limit)

62 MPa9 ksi
68 MPa9.9 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

44 HB
48 HB

Hardness, Vickers

46 HV
50 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Elongation at Break 40%

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 355 W/m·K205 BTU/hr·ft·°F · Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 92 % IACS · Electrical Resistivity 1.87×10⁻⁸ Ω·m0.736 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 25 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 60 / 100 · Formability (cold) 40 / 100 · Castability 50 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC80500

C80500-M01 vs C80500-M02 — frequently asked

Is C80500-M02 stronger than C80500-M01?

Yes. C80500-M02 has a typical yield strength of 70 MPa (10.2 ksi) against 62 MPa (8.99 ksi) for C80500-M01 — about 13% more. Tensile strength is 195 MPa (28.3 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, M01 or M02?

M01 is the default C80500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C80500-M01 over C80500-M02?

Pick C80500-M02 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C80500-M01 and C80500-M02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.