C77400-H02 and C77400-H04 are two conditions of the same copper alloy grade, C77400: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C77400-H04 is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 440 MPa (63.8 ksi) for C77400-H02, about 25% more; tensile strength follows at 620 MPa (89.9 ksi) vs 515 MPa (74.7 ksi). In exchange, C77400-H02 is the more ductile: elongation 10% versus 3% for C77400-H04, and C77400-H04 is harder (175 HB vs 145 HB). C77400-H02 runs hotter in service (200°C vs 175°C continuous).

C77400-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C77400-H04Choose it when strength drives the design.

C77400-H02 vs C77400-H04: properties

C77400-H02C77400-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

515 MPa74.7 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

440 MPa63.8 ksi
550 MPa79.8 ksi

Elongation at Break

10%
3%

Shear Strength

330 MPa47.9 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

215 MPa31.2 ksi
235 MPa34.1 ksi

Hardness, Brinell

145 HB
175 HB

Hardness, Rockwell B

78 HRB
87 HRB

Hardness, Vickers

150 HV
185 HV

Same in both: Elastic (Young's) Modulus 125 GPa18.1 Msi · Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 122 GPa17.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.7 g/cm³0.31 lb/in³ · Melting Point (Solidus) 960°C1,760 °F · Liquidus Temperature 1,010°C1,850 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
175°C347 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 11 % IACS · Electrical Resistivity 1.57×10⁻⁷ Ω·m6.18 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

20%
25%

Formability (cold)

80 / 100
55 / 100

Same in both: Machinability 25 / 100 · Weldability 50 / 100 · Brazeability / Solderability 85 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC77400

C77400-H02 vs C77400-H04 — frequently asked

Is C77400-H04 stronger than C77400-H02?

Yes. C77400-H04 has a typical yield strength of 550 MPa (79.8 ksi) against 440 MPa (63.8 ksi) for C77400-H02 — about 25% more. Tensile strength is 620 MPa (89.9 ksi) vs 515 MPa (74.7 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H02 is the default C77400 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C77400-H02 over C77400-H04?

Pick C77400-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C77400-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C77400-H02 and C77400-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.