FabDigitFabDigit

Copper Alloy C75700-H02 vs C75700-H04

Copper Alloy · C75700 temper comparison

C75700-H02 and C75700-H04 are two conditions of the same copper alloy grade, C75700: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C75700-H04 is the stronger of the two: yield strength 505 MPa (73.2 ksi) against 420 MPa (60.9 ksi) for C75700-H02, about 20% more; tensile strength follows at 565 MPa (81.9 ksi) vs 496 MPa (71.9 ksi). In exchange, C75700-H02 is the more ductile: elongation 10% versus 4% for C75700-H04, and C75700-H04 is harder (165 HB vs 135 HB). C75700-H02 runs hotter in service (200°C vs 180°C continuous).

C75700-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C75700-H04Choose it when strength drives the design.

C75700-H02 vs C75700-H04: properties

C75700-H02C75700-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

496 MPa71.9 ksi
565 MPa81.9 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
505 MPa73.2 ksi

Elongation at Break

10%
4%

Shear Strength

320 MPa46.4 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
195 MPa28.3 ksi

Hardness, Brinell

135 HB
165 HB

Hardness, Rockwell B

74 HRB
84 HRB

Hardness, Vickers

145 HV
175 HV

Same in both: Elastic (Young's) Modulus 124 GPa18 Msi · Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 130 GPa18.9 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.72 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,004°C1,839 °F · Liquidus Temperature 1,038°C1,900 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
180°C356 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 180 J/g77.4 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.92×10⁻⁷ Ω·m7.56 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Formability (cold)

55 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 40 / 100 · Brazeability / Solderability 80 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 65 MJ/kg27,945 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC75700

C75700-H02 vs C75700-H04 — frequently asked

Is C75700-H04 stronger than C75700-H02?

Yes. C75700-H04 has a typical yield strength of 505 MPa (73.2 ksi) against 420 MPa (60.9 ksi) for C75700-H02 — about 20% more. Tensile strength is 565 MPa (81.9 ksi) vs 496 MPa (71.9 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H02 is the default C75700 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C75700-H02 over C75700-H04?

Pick C75700-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C75700-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C75700-H02 and C75700-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.