FabDigitFabDigit

Copper Alloy C74500-H02 vs C74500-H04

Copper Alloy · C74500 temper comparison

C74500-H02 and C74500-H04 are two conditions of the same copper alloy grade, C74500: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C74500-H04 is the stronger of the two: yield strength 515 MPa (74.7 ksi) against 400 MPa (58 ksi) for C74500-H02, about 29% more; tensile strength follows at 585 MPa (84.8 ksi) vs 510 MPa (74 ksi). In exchange, C74500-H02 is the more ductile: elongation 12% versus 4% for C74500-H04, and C74500-H04 is harder (175 HB vs 150 HB). C74500-H02 runs hotter in service (180°C vs 150°C continuous).

C74500-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C74500-H04Choose it when strength drives the design.

C74500-H02 vs C74500-H04: properties

C74500-H02C74500-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

510 MPa74 ksi
585 MPa84.8 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
515 MPa74.7 ksi

Elongation at Break

12%
4%

Shear Strength

330 MPa47.9 ksi
360 MPa52.2 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
195 MPa28.3 ksi

Hardness, Brinell

150 HB
175 HB

Hardness, Rockwell B

80 HRB
87 HRB

Hardness, Vickers

158 HV
185 HV

Same in both: Elastic (Young's) Modulus 127 GPa18.4 Msi · Shear Modulus 48 GPa7 Msi · Bulk Modulus 128 GPa18.6 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.73 g/cm³0.32 lb/in³ · Melting Point (Solidus) 954°C1,749 °F · Liquidus Temperature 1,021°C1,870 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
150°C302 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 195 J/g83.8 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.92×10⁻⁷ Ω·m7.56 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Formability (cold)

60 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 40 / 100 · Brazeability / Solderability 88 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC74500

C74500-H02 vs C74500-H04 — frequently asked

Is C74500-H04 stronger than C74500-H02?

Yes. C74500-H04 has a typical yield strength of 515 MPa (74.7 ksi) against 400 MPa (58 ksi) for C74500-H02 — about 29% more. Tensile strength is 585 MPa (84.8 ksi) vs 510 MPa (74 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H02 is the default C74500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C74500-H02 over C74500-H04?

Pick C74500-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C74500-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C74500-H02 and C74500-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.