FabDigitFabDigit

Copper Alloy C71520-H02 vs C71520-M10

Copper Alloy · C71520 temper comparison

C71520-H02 and C71520-M10 are two conditions of the same copper alloy grade, C71520: H02 (half hard) versus M10 (as hot forged and air cooled). The chemistry is identical, so every difference below comes from the condition. C71520-H02 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 165 MPa (23.9 ksi) for C71520-M10, about 152% more; tensile strength follows at 505 MPa (73.2 ksi) vs 380 MPa (55.1 ksi). In exchange, C71520-M10 is the more ductile: elongation 40% versus 15% for C71520-H02, and C71520-H02 is harder (150 HB vs 95 HB). C71520-M10 runs hotter in service (350°C vs 300°C continuous).

C71520-H02Choose it when strength drives the design.

C71520-M10Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C71520-H02 vs C71520-M10: properties

C71520-H02C71520-M10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

505 MPa73.2 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
165 MPa23.9 ksi

Elongation at Break

15%
40%

Reduction in Area

35%
55%

Shear Strength

300 MPa43.5 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
145 MPa21 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

150 HB
95 HB

Hardness, Rockwell B

78 HRB
50 HRB

Hardness, Vickers

160 HV
100 HV

Same in both: Elastic (Young's) Modulus 152 GPa22 Msi · Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 158 GPa22.9 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,171°C2,140 °F · Liquidus Temperature 1,238°C2,260 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
350°C662 °F

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 215 J/g92.4 BTU/lb · Min Service Temperature -198°C-324 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

4.5 % IACS
4.6 % IACS

Electrical Resistivity

3.83×10⁻⁷ Ω·m15.1 µΩ·in
3.75×10⁻⁷ Ω·m14.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
20%

Weldability

85 / 100
88 / 100

Formability (cold)

45 / 100
75 / 100

Same in both: Castability 50 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 90 MJ/kg38,693 BTU/lb · Embodied Carbon (primary production) 6.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC71520

C71520-H02 vs C71520-M10 — frequently asked

Is C71520-H02 stronger than C71520-M10?

Yes. C71520-H02 has a typical yield strength of 415 MPa (60.2 ksi) against 165 MPa (23.9 ksi) for C71520-M10 — about 152% more. Tensile strength is 505 MPa (73.2 ksi) vs 380 MPa (55.1 ksi).

Which condition does FabDigit quote by default, H02 or M10?

O60 is the default C71520 condition in the FabDigit quote flow (neither H02 nor M10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C71520-H02 or C71520-M10?

C71520-H02, by a small margin. Both rate poor for machinability — 30/100 against 25/100 for C71520-M10.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C71520-H02 and C71520-M10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.