FabDigitFabDigit

Copper Alloy C71520-AW vs C71520-H02

Copper Alloy · C71520 temper comparison

C71520-AW and C71520-H02 are two conditions of the same copper alloy grade, C71520: AW (as-welded deposit) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. C71520-H02 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 250 MPa (36.3 ksi) for C71520-AW, about 66% more; tensile strength follows at 505 MPa (73.2 ksi) vs 400 MPa (58 ksi). In exchange, C71520-AW is the more ductile: elongation 30% versus 15% for C71520-H02, and C71520-H02 is harder (150 HB vs 105 HB). C71520-AW runs hotter in service (350°C vs 300°C continuous).

C71520-AWChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C71520-H02Choose it when strength drives the design.

C71520-AW vs C71520-H02: properties

C71520-AWC71520-H02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

150 GPa21.8 Msi
152 GPa22 Msi

Tensile Strength (Ultimate)

400 MPa58 ksi
505 MPa73.2 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
415 MPa60.2 ksi

Elongation at Break

30%
15%

Reduction in Area

40%
35%

Shear Strength

250 MPa36.3 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
180 MPa26.1 ksi

Charpy V-Notch Impact (RT)

85 J62.7 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

105 HB
150 HB

Hardness, Rockwell B

55 HRB
78 HRB

Hardness, Vickers

112 HV
160 HV

Same in both: Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 158 GPa22.9 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,171°C2,140 °F · Liquidus Temperature 1,238°C2,260 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

27 W/m·K15.6 BTU/hr·ft·°F
29 W/m·K16.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 215 J/g92.4 BTU/lb · Min Service Temperature -198°C-324 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

4.3 % IACS
4.5 % IACS

Electrical Resistivity

4×10⁻⁷ Ω·m15.7 µΩ·in
3.83×10⁻⁷ Ω·m15.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

79 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
22%

Weldability

90 / 100
85 / 100

Formability (cold)

60 / 100
45 / 100

Same in both: Castability 50 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 90 MJ/kg38,693 BTU/lb · Embodied Carbon (primary production) 6.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC71520

C71520-AW vs C71520-H02 — frequently asked

Is C71520-H02 stronger than C71520-AW?

Yes. C71520-H02 has a typical yield strength of 415 MPa (60.2 ksi) against 250 MPa (36.3 ksi) for C71520-AW — about 66% more. Tensile strength is 505 MPa (73.2 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, AW or H02?

O60 is the default C71520 condition in the FabDigit quote flow (neither AW nor H02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C71520-AW or C71520-H02?

C71520-H02, by a small margin. Both rate poor for machinability — 30/100 against 22/100 for C71520-AW; for welding the order is C71520-AW first (excellent, 90/100) then C71520-H02 (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C71520-AW and C71520-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.