FabDigitFabDigit

Copper Alloy C70700-H01 vs C70700-M20

Copper Alloy · C70700 temper comparison

C70700-H01 and C70700-M20 are two conditions of the same copper alloy grade, C70700: H01 (quarter hard) versus M20 (as hot rolled). The chemistry is identical, so every difference below comes from the condition. C70700-H01 is the stronger of the two: yield strength 240 MPa (34.8 ksi) against 125 MPa (18.1 ksi) for C70700-M20, about 92% more; tensile strength follows at 345 MPa (50 ksi) vs 305 MPa (44.2 ksi). In exchange, C70700-M20 is the more ductile: elongation 35% versus 30% for C70700-H01, and C70700-H01 is harder (100 HB vs 70 HB). C70700-M20 runs hotter in service (350°C vs 250°C continuous).

C70700-H01Choose it when strength drives the design.

C70700-M20Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C70700-H01 vs C70700-M20: properties

C70700-H01C70700-M20

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

345 MPa50 ksi
305 MPa44.2 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
125 MPa18.1 ksi

Elongation at Break

30%
35%

Reduction in Area

55%
60%

Shear Strength

245 MPa35.5 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
138 MPa20 ksi

Charpy V-Notch Impact (RT)

100 J73.8 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

100 HB
70 HB

Hardness, Rockwell B

52 HRB
32 HRB

Hardness, Vickers

108 HV
80 HV

Same in both: Elastic (Young's) Modulus 124 GPa18 Msi · Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,100°C2,012 °F · Liquidus Temperature 1,145°C2,093 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
350°C662 °F

Same in both: Thermal Conductivity 40 W/m·K23.1 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.1 µm/m·K9.5 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

9.3 % IACS
9.5 % IACS

Electrical Resistivity

1.95×10⁻⁷ Ω·m7.68 µΩ·in
1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
28 / 100

Weldability

85 / 100
88 / 100

Formability (cold)

75 / 100
80 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Castability 45 / 100 · Brazeability / Solderability 88 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 70 MJ/kg30,095 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC70700

C70700-H01 vs C70700-M20 — frequently asked

Is C70700-H01 stronger than C70700-M20?

Yes. C70700-H01 has a typical yield strength of 240 MPa (34.8 ksi) against 125 MPa (18.1 ksi) for C70700-M20 — about 92% more. Tensile strength is 345 MPa (50 ksi) vs 305 MPa (44.2 ksi).

Which condition does FabDigit quote by default, H01 or M20?

O61 is the default C70700 condition in the FabDigit quote flow (neither H01 nor M20). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C70700-H01 over C70700-M20?

Pick C70700-H01 when strength drives the design. Pick C70700-M20 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C70700-H01 and C70700-M20 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.