FabDigitFabDigit

Copper Alloy C70700-H01 vs C70700-H80

Copper Alloy · C70700 temper comparison

C70700-H01 and C70700-H80 are two conditions of the same copper alloy grade, C70700: H01 (quarter hard) versus H80 (hard drawn). The chemistry is identical, so every difference below comes from the condition. C70700-H80 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 240 MPa (34.8 ksi) for C70700-H01, about 58% more; tensile strength follows at 415 MPa (60.2 ksi) vs 345 MPa (50 ksi). In exchange, C70700-H01 is the more ductile: elongation 30% versus 12% for C70700-H80, and C70700-H80 is harder (145 HB vs 100 HB).

C70700-H01Choose it when the part is bent, formed or impact-loaded.

C70700-H80Choose it when strength drives the design.

C70700-H01 vs C70700-H80: properties

C70700-H01C70700-H80

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

345 MPa50 ksi
415 MPa60.2 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
380 MPa55.1 ksi

Elongation at Break

30%
12%

Reduction in Area

55%
32%

Shear Strength

245 MPa35.5 ksi
265 MPa38.4 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
175 MPa25.4 ksi

Charpy V-Notch Impact (RT)

100 J73.8 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

100 HB
145 HB

Hardness, Rockwell B

52 HRB
75 HRB

Hardness, Vickers

108 HV
152 HV

Same in both: Elastic (Young's) Modulus 124 GPa18 Msi · Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,100°C2,012 °F · Liquidus Temperature 1,145°C2,093 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 40 W/m·K23.1 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.1 µm/m·K9.5 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.3 % IACS · Electrical Resistivity 1.95×10⁻⁷ Ω·m7.68 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
77 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
23%

Weldability

85 / 100
80 / 100

Formability (cold)

75 / 100
45 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 88 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 70 MJ/kg30,095 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC70700

C70700-H01 vs C70700-H80 — frequently asked

Is C70700-H80 stronger than C70700-H01?

Yes. C70700-H80 has a typical yield strength of 380 MPa (55.1 ksi) against 240 MPa (34.8 ksi) for C70700-H01 — about 58% more. Tensile strength is 415 MPa (60.2 ksi) vs 345 MPa (50 ksi).

Which condition does FabDigit quote by default, H01 or H80?

O61 is the default C70700 condition in the FabDigit quote flow (neither H01 nor H80). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, C70700-H01 or C70700-H80?

C70700-H01. Its weldability rates excellent (85/100) against very good (80/100) for C70700-H80.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C70700-H01 and C70700-H80 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.