C70600-H02 and C70600-O60 are two conditions of the same copper alloy grade, C70600: H02 (half hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C70600-H02 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 110 MPa (16 ksi) for C70600-O60, about 3.5 times as much; tensile strength follows at 415 MPa (60.2 ksi) vs 300 MPa (43.5 ksi). In exchange, C70600-O60 is the more ductile: elongation 42% versus 10% for C70600-H02, and C70600-H02 is harder (125 HB vs 60 HB). On the shop floor, C70600-H02 machines more easily (fair vs poor).

C70600-H02Choose it when strength drives the design, or when the part is machined in volume.

C70600-O60Choose it when the part is bent, formed or impact-loaded.

C70600-H02 vs C70600-O60: properties

C70600-H02C70600-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

415 MPa60.2 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
110 MPa16 ksi

Elongation at Break

10%
42%

Shear Strength

255 MPa37 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
125 MPa18.1 ksi

Hardness, Brinell

125 HB
60 HB

Hardness, Rockwell B

72 HRB
20 HRB

Hardness, Vickers

140 HV
65 HV

Same in both: Elastic (Young's) Modulus 124 GPa18 Msi · Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 130 GPa18.9 Msi · Poisson's Ratio 0.33 · Reduction in Area 60%

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,100°C2,012 °F · Liquidus Temperature 1,145°C2,093 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

38 W/m·K22 BTU/hr·ft·°F
40 W/m·K23.1 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -195°C-319 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

9.2 % IACS
9.5 % IACS

Same in both: Electrical Resistivity 1.82×10⁻⁷ Ω·m7.17 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

76 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
26 / 100

Weldability

85 / 100
92 / 100

Formability (cold)

55 / 100
92 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Castability 45 / 100 · Brazeability / Solderability 88 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC70600

C70600-H02 vs C70600-O60 — frequently asked

Is C70600-H02 stronger than C70600-O60?

Yes. C70600-H02 has a typical yield strength of 380 MPa (55.1 ksi) against 110 MPa (16 ksi) for C70600-O60 — about 3.5 times as much. Tensile strength is 415 MPa (60.2 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, H02 or O60?

OS050 is the default C70600 condition in the FabDigit quote flow (neither H02 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C70600-H02 or C70600-O60?

C70600-H02. Its machinability rates fair (38/100) against poor (26/100) for C70600-O60; for welding the order is C70600-O60 first (excellent, 92/100) then C70600-H02 (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C70600-H02 and C70600-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.