FabDigitFabDigit

Copper Alloy C70250-TD04 vs C70250-TM08

Copper Alloy · C70250 temper comparison

C70250-TD04 and C70250-TM08 are two conditions of the same copper alloy grade, C70250: TD04 (solution heat treated and cold worked, full hard) versus TM08 (mill hardened, spring hard). The chemistry is identical, so every difference below comes from the condition. C70250-TM08 is the stronger of the two: yield strength 800 MPa (116 ksi) against 520 MPa (75.4 ksi) for C70250-TD04, about 54% more; tensile strength follows at 845 MPa (123 ksi) vs 570 MPa (82.7 ksi). In exchange, C70250-TD04 is the more ductile: elongation 6% versus 4% for C70250-TM08, and C70250-TM08 is harder (240 HV vs 165 HV). C70250-TM08 runs hotter in service (200°C vs 150°C continuous) and C70250-TM08 conducts heat better (148 W/m·K vs 100 W/m·K).

C70250-TD04Choose it when the part is bent, formed or impact-loaded.

C70250-TM08Choose it when strength drives the design, or when the part sees heat.

C70250-TD04 vs C70250-TM08: properties

C70250-TD04C70250-TM08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

130 GPa18.9 Msi
132 GPa19.1 Msi

Tensile Strength (Ultimate)

570 MPa82.7 ksi
845 MPa123 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
800 MPa116 ksi

Elongation at Break

6%
4%

Shear Strength

345 MPa50 ksi
510 MPa74 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
335 MPa48.6 ksi

Hardness, Rockwell B

85 HRB
99 HRB

Hardness, Vickers

165 HV
240 HV

Same in both: Shear Modulus 50 GPa7.3 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.82 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,095°C2,003 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

100 W/m·K57.8 BTU/hr·ft·°F
148 W/m·K85.5 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

24 % IACS
37 % IACS

Electrical Resistivity

7.18×10⁻⁸ Ω·m2.83 µΩ·in
4.66×10⁻⁸ Ω·m1.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
33%

Formability (cold)

45 / 100
35 / 100

Same in both: Weldability 35 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC70250

C70250-TD04 vs C70250-TM08 — frequently asked

Is C70250-TM08 stronger than C70250-TD04?

Yes. C70250-TM08 has a typical yield strength of 800 MPa (116 ksi) against 520 MPa (75.4 ksi) for C70250-TD04 — about 54% more. Tensile strength is 845 MPa (123 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, TD04 or TM08?

TM02 is the default C70250 condition in the FabDigit quote flow (neither TD04 nor TM08). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C70250-TD04 or C70250-TM08?

C70250-TM08. Its machinability rates fair (38/100) against poor (33/100) for C70250-TD04.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C70250-TD04 and C70250-TM08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.